Opticis M1-1POE-30 ユーザーズマニュアル

ページ / 8
 
M1-1P0E (Ver. 1.2)
 
 
 
Copyright ©  2012, All rights reserved, Opticis Co., Ltd.  
 
Aug. 03, 2012 
 
- 6 - 
www.opticis.com 
 
Reliability Test 
 
Opticis utilizes three types of test criteria for a reduction of variability and a continuous improvement of 
the process by its FEMA (Failure Mode and Effective Analysis) program. 
1)  Mechanical test (vibration, shock) 
2)  Temperature & humidity tests 
3)  EMC test (FCC class A and CE Verification
 
Mechanical and Temperature & Humidity Test Data 
 
Heading 
Test 
Conditions 
Duration 
Sample 
Size 
Failure 
Remarks 
Operating 
Test 
Operating at each 
Temperature 
(See Note)
 
* - 0 ~ 50 °C 
(Interval: 10 °C) 
30 Min 
(Each 
Temperature) 
n =4 
Note: 
Visual 
Test 
on             
the Display 
Storage 
Test 
Low Temperature 
* T
S
 = -30 °C 
96 HR 
n=2 
1. TS: Storage Temperature 
High Temperature 
* T
S
 = 70 °C 
96 HR 
n=2 
2. RH: Relative Humidity 
High Humidity 
High Temperature 
* T
S
: 85 °C 
* RH: 85% 
96 HR 
n=2 
 
Mechanical 
Test 
Mechanical 
Shock 
* Pulse: 11 ms 
* Peak level: 30 g 
* Shock pulse: 3 times/Axis 
n=2 
 
Mechanical 
Vibration 
* Peak acceleration: 20 g 
* Frequency: 20~2000 ㎐ 
* Sweep time: 30 Minutes 
* 4 Times/Axis 
n=2