Model #: SU8000RT3UN50TF
SmartOnline 8kVA On-Line Double-Conversion UPS, 8U Rack/Tower, 208/120V NEMA outlets, 50A plug
 
Highlights
8kVA / 8000VA / 7200W on-line double-conversion UPS; 0.9 power factor
208/120V 60Hz output; Economy mode option
8U Rack/Tower configuration; Hot-swap power and battery modules
USB, RS232 & EPO ports; SNMP/WEB and contact-closure card options
Front panel LEDs with detailed LCD monitoring and control screen
Expandable runtime with optional external battery packs
Hubbell CS8265 input (3 wire); L6-30R, L6-20R & 5-15/20R outlets
Description
Tripp Lite SU8000RT3UN50TF 8000VA / 8kVA / 7200 watt online, double-conversion UPS system offers complete power protection for critical
network applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking
applications. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included
detachable PDU with manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected
equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking
applications in data centers, computer rooms, network closets and rugged industrial locations.
Package Includes
SU8000RT3UPM 3U UPS power module
BP240V10RT3U external battery pack
SU5000XFMRT2U step down transformer
SUPDMB710 Detachable PDU with manual bypass switch
Four post compatible rack rail kit (3 sets)
Tower stands for upright tower configuration
PowerAlert software, complete data cabling and user manual
Features
Tripp Lite SU8000RT3UN50TF 8kVA / 8000VA / 7200 watt on-line, double-conversion UPS system in 8U total rack/tower configuration (3U
UPS power module, 3U external battery pack and 2U step-down transformer)
Detachable PDU with manual bypass switch enables hot-swappable UPS power module replacement with no interruption in output power to
connected networking equipment
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Hubbell CS8265 (208V 50A) or Hardwire input; 2 L6-30R, 4 L6-20R and 12 5-15/20R outlets
Maximum installed rack depth of only 32.5 in. / 82.6cm inches
Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions
and line noise
Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with
enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS
types