Zebra HW46211 Manual De Usuario

Descargar
Página de 275
13185L-002 Rev. A  1/24/06
110XiIIIPlus Maintenance Manual
Page 4-101
Maintenance
Section 4
Twinax Communications Interface Board
Install Instructions
1. Refer to 
. Turn the power Off (O) and disconnect the AC 
power cord. Disconnect any data cables.
2.
 and remove the electronics cover.
3. Refer to 
. At the rear of the printer, remove and retain the two screws 
and the blank cover plate or existing interface board positioned next to the main 
RS-232 and parallel interface connectors.
Note • To print a PrintServer II configuration label from your Zebra printer, a 
4 in. wide by 6 in. long (100 mm wide by 150 mm long) label is recommended. If 
the label is smaller, some information may print outside the label edges. Some 
of the heading information on the right side of the label will not print. Refer to 
 for any missing data.
Caution:
The printer electronics are susceptible to static discharge. Before proceeding, it 
is highly recommended that the technician wear an antistatic wrist strap 
connected to the printer chassis.
Caution:
Unless indicated otherwise, turn the printer Off (O) and disconnect the printer 
from the power source before performing the following maintenance.
Caution:
This installation must be performed by a qualified service technician.