Black Box LGC5950C-R2 Manual De Usuario

Descargar
Página de 13
BLACK BOX
®
  3 of 13
11/1/2010 
#24435
LMC5207A-R2
(with modules installed)
Get full control of your media converter connections in your 
enterprise by ordering a 
High-Density Media Converter System II 
Chassis
 as well as a plug-in 
SNMP Management Module
Choose from a desktop 3-slot chassis, a 1U rackmount or desktop 
6-slot chassis, or a 3U rackmount 20-slot chassis (the chassis ship with 
blank plates already installed, and the 6- and 20-slot models include 
rackmounting hardware). 
Each chassis has one additional slot for the 
SNMP Management 
Module
, which you order separately and install in the chassis to enable 
both module and chassis management. You can even install chassis as 
an unmanaged chassis and then add SNMP later—a perfect solution 
for an unmanaged network that might migrate to a managed one at a 
later date. 
Module’s GUI gives you detailed conversion ports info.
The 
SNMP Management Module
 not only also includes MIBs for 
SNMP; it also comes with a CD-ROM that contains iView management 
software. This software enables you to configure the chassis and the 
media converter modules plugged into it in minutes and provides you 
with a cross-platform application for managing intelligent networking 
devices from virtually any 32-bit Windows
®
 system. The module is 
compatible with Windows
®
 as well as HTML.
The user-friendly, comprehensive iView program uses a clear 
graphical user interface (GUI). This shows an on-screen representation 
of the actual device control panels and gives you detailed information 
about the conversion ports.
You can also use the module’s included MIBs with any standard 
SNMP program, such as HP
®
 OpenView
®
. This enables you to view 
SNMP’s in-depth technical data in the easy-to-use iView interface.  
You can even display statistics as charts.
Lock in SNMP configuration and specify backup power.
In situations where you need to disable chassis manage ment, 
simply move the SNMP switch to the off position. Even though this 
makes the modules unmanageable, the SNMP agent continues to 
communicate with installed modules. Turning management back on 
returns the modules to manage ment control and any settings you’ve 
set in iView.
For peace of mind, an SNMP write-lock switch protects 
the configurations of your installed modules from being accidentally 
overwritten. Even better, the SNMP slot saves your SNMP settings even 
when the 
SNMP Management Module
 is removed from the chassis.
And, for the chassis themselves, we offer redundant power 
supplies, which help you isolate mission-critical applications from 
points of failure. A “last gasp” feature alerts you when one of the 
power supplies or AC power fails. What’s more, the 3-slot chassis can 
even be configured with both an AC and a DC power supply, enabling 
you to fall back on DC power should your AC power fail. 
And there are even more features to ensure reliability:  
High-Density Media Converter System II Chassis with Modular SNMP
The 20-slot chassis has dual fans that are easily field replaceable,  
and the 3-slot and 6-slot chassis boast a fan test feature and have fans 
that activate only when the chassis reaches a preset temperature. Fan 
speed and chassis temperature can be monitored remotely via SNMP. 
Connect to your network and configure with ease.
The chassis connects to your LAN via an external 10BASE-T/ 
100BASE-TX twisted-pair connection on the installed 
SNMP 
Management Module
. Simply plug one end of a CAT5 or higher 
UTP cable into the module’s MGMT port and plug the other end  
into a switch, hub, or other networking device on your LAN.
Because the twisted-pair port has an auto-cross design,  
it automatically enables either a crossover or a straight-through 
connection to match the pinning of your connected device. 
No crossover cables are required!
Once you connect a chassis to your network, you can assign  
the device its own IP address.
This initial IP address configuration can be done in-band through 
the management module’s twisted-pair port while using the 
HubControl utility (included on the iView CD) or out-of-band through 
the management module’s RS-232 port using Dynamic Host 
Configuration Protocol (DHCP). (Because the chassis has an embedded 
DHCP agent, its IP address is dynamically assigned when connected to 
a LAN with a DHCP server.) The 
SNMP Management Module
 also 
includes a TFTP client and supports Telnet
.
Of the two IP address assignment routes, the second is the 
simplest. Simply plug the included straight-through-pinned cable into 
the module’s DB9 connector and the other end into the appropriate 
port on your computer or terminal that’s set for VT100
 emulation. 
The HubControl utility can also be used to initiate remote SNMP 
configuration for SNMP-manageable devices. This way, you can get  
a head start on adding subnet masks, trap assignments, and other 
management functions. You can also use HubControl to upload new 
versions of the system software and new MIB information.
Once the chassis has an IP address assigned, use the iView software 
or another SNMP-compatible network management system, such as 
HP OpenView, to remotely configure, monitor, and manage the 
modules you install in the chassis. Program subnet masks and default 
gateways, create community strings (for both read-only and read/write 
access), configure traps—all within a password-protection process!
VLAN tagging enables you to separate each user’s traffic into  
a separate and secure data stream. These converters also support 
802.1Q “Q-in-Q” extra tagging. 
Managed modules and media converters
Managed High-Density Media Converter System II Modules 
and
 
Multiport Managed Media Converters 
(page 13) offer the same 
management features as the SNMP module, but can be managed 
independently of a chassis with an SNMP Management Module.