Intel S1400SP4 DBS1400SP4 Manual De Usuario

Los códigos de productos
DBS1400SP4
Descargar
Página de 159
Intel® Server Board S1400SP TPS 
 
Intel® Light Guided Diagnostics 
Revision 1.0 
 
 
Intel order number G64248-001 
97 
Table 49. System Status LED State Definitions 
Color 
State 
Criticality 
Description 
Green 
Solid on 
Ok 
Indicates that the System Status is ‗Healthy‘. The system is not 
exhibiting any errors. AC power is present and BMC has booted and 
manageability functionality is up and running.  
 
Green 
~1 Hz blink 
Degraded 
System degraded: 
 
1. Redundancy loss such as power-supply or fan. Applies only if the 
associated platform sub-system has redundancy capabilities.  
2. Fan warning or failure when the number of fully operational fans is 
more than minimum number needed to cool the system.  
3. Non-critical threshold crossed – Temperature (including HSBP 
temp), voltage, input power to power supply, output current for main 
power rail from power supply and Processor Thermal Control (Therm 
Ctrl) sensors.  
4. Power supply predictive failure occurred while redundant power 
supply configuration was present.  
5. Unable to use all of the installed memory (more than 1 DIMM 
installed) 
6. Correctable Errors over a threshold and migrating to a spare DIMM 
(memory sparing). This indicates that the user no longer has spared 
DIMMs indicating a redundancy lost condition. Corresponding DIMM 
LED lit.  
7. In mirrored configuration, when memory mirroring takes place and 
system loses memory redundancy.  
8. Battery failure.  
9. BMC executing in uBoot. (Indicated by Chassis ID blinking at 
Blinking at 3Hz). System in degraded state (no manageability). BMC 
uBoot is running but has not transferred control to BMC Linux*. 
Server will be in this state 6-8 seconds after BMC reset while it pulls 
the Linux* image into flash  
10. BMC booting Linux*. (Indicated by Chassis ID solid ON). System 
in degraded state (no manageability). Control has been passed from 
BMC uBoot to BMC Linux* itself. It will be in this state for ~10-~20 
seconds.  
11. BMC Watchdog has reset the BMC.  
12. Power Unit sensor offset for configuration error is asserted.  
13. HDD HSC is off-line or degraded.  
 
Amber 
~1 Hz blink 
Non-critical 
Non-fatal alarm – system is likely to fail: 
 
1. Critical threshold crossed – Voltage, temperature (including HSBP 
temp), input power to power supply, output current for main power rail 
from power supply and PROCHOT (Therm Ctrl) sensors.  
2. VRD Hot asserted.  
3. Minimum number of fans to cool the system not present or failed  
4. Hard drive fault  
5. Power Unit Redundancy sensor – Insufficient resources offset 
(indicates not enough power supplies present)  
6. In non-sparing and non-mirroring mode if the threshold of 
correctable errors is crossed within the window1