Intel S1400SP4 DBS1400SP4 Manual De Usuario

Los códigos de productos
DBS1400SP4
Descargar
Página de 159
Intel® Server Board S1400SP TPS 
 
Intel® Light Guided Diagnostics 
Revision 1.0 
 
 
Intel order number G64248-001 
99 
condition during the POST process. The diagnostic LEDs can be used to identify the last POST 
process to be executed. See Appendix D for a complete description of how these LEDs are 
read, and for a list of all supported POST codes. 
10.5  5 Volt Stand-By Present LED 
This LED is illuminated when a power cord (AC or DC) is connected to the server and the power 
supply is supplying 5 Volt Stand-by power to the server board. This LED is intended as a 
service caution indicator to anyone accessing the inside of the server system.  
10.6  Fan Fault LEDs 
The server board includes a Fan Fault LED next to each of the six system fans and both CPU 
fans. The LED has two states: On and Off. The BMC lights a fan fault LED if the associated fan-
tach sensor has a lower critical threshold event status asserted. Fan-tach sensors are manual 
re-arm sensors. Once the lower critical threshold is crossed, the LED remains lit until the sensor 
is rearmed. These sensors are rearmed at system DC power-on and system reset. 
10.7  Memory Fault LEDs 
The server board includes a Memory Fault LED for each DIMM slot. When the BIOS detects a 
memory fault condition, it sends an IPMI OEM command (Set Fault Indication) to the BMC to 
instruct the BMC to turn on the associated Memory Slot Fault LED. These LEDs are only active 
when the system is in the ‘on’ state. The BMC will not activate or change the state of the LEDs 
unless instructed by the BIOS.