On-board Connector/Header Overview 
Intel® Server Board S1400SP TPS 
 
 
Revision 1.0 
Intel order number G64248-001 
86 
Table 33. SSI 4-pin Fan Header Pin-out  
Pin 
Signal Name 
Type 
Description 
Ground 
GND 
Ground is the power supply ground 
12V 
Power 
Power supply 12 V 
Fan Tach 
In 
FAN_TACH signal is connected to the BMC to monitor the fan speed  
Fan PWM 
Out 
FAN_PWM signal to control fan speed 
Table 34. 10-pin Fan Header Pin-out  
SYS_FAN 1 
SYS_FAN 2 
SYS_FAN 3 
Signal Description 
Pin# 
Signal Description 
Pin# 
Signal Description 
Pin# 
FAN_TACH1_IN 
FAN_TACH3_IN 
FAN_TACH5_IN 
FAN_PWM_OUT_SYS1 
FAN_PWM_OUT_SYS2 
FAN_PWM_OUT_SYS3 
P12V_SYS_FAN12 
P12V_SYS_FAN12 
P12V_SYS_FAN34 
P12V_SYS_FAN12 
P12V_SYS_FAN12 
P12V_SYS_FAN34 
FAN_TACH0_IN 
FAN_TACH2_IN 
FAN_TACH4_IN 
GROUND 
GROUND 
GROUND 
GROUND 
GROUND 
GROUND 
FAN_SYS1_PRSNT_BAT_N 
FAN_SYS2_PRSNT_BAT_N 
FAN_SYS3_PRSNT_BAT_N 
LED_FAN_FAULT0_R 
LED_FAN_FAULT1_R 
LED_FAN_FAULT2_R 
LED_FAN0 
10 
LED_FAN1 
10 
LED_FAN2 
10 
SYS_FAN 4 
SYS_FAN 5 
 
Signal Description 
Pin# 
Signal Description 
 
 
 
FAN_TACH7_IN 
FAN_TACH9_IN 
 
 
FAN_PWM_OUT_SYS4 
FAN_PWM_OUT_SYS5 
 
 
P12V_SYS_FAN34 
P12V_SYS_FAN5 
 
 
P12V_SYS_FAN34 
P12V_SYS_FAN5 
 
 
FAN_TACH6_IN 
FAN_TACH8_IN 
 
 
GROUND 
GROUND 
 
 
GROUND 
GROUND 
 
 
FAN_SYS4_PRSNT_BAT_N 
FAN_SYS5_PRSNT_BAT_N 
 
 
LED_FAN_FAULT3_R 
LED_FAN_FAULT4_R 
 
 
LED_FAN3 
10 
LED_FAN4 
10 
 
 
8.6  Serial Port Connector 
The server board includes two serial port connectors. Serial-A is an external RJ45 type 
connector and has the following pin-out configuration. 
 
Table 35. Serial A Connector Pin-out 
Signal Description  Pin# 
RTS 
DTR 
SOUT 
GROUND 
RI 
SIN 
DSR 
CTS