2-4
Connecting Voltage Measurement Cables
Connecting Voltage Measurement Cables
Measurement 
cable set
Description: Voltage measurement cables are provided as standard accessories and are 
stored in a cable pouch as part of the measurement cable set, P/N 116042-G6. Each 
cable set consists of a cable and alligator clip.
Voltage Rating: Direct connection of all voltage measurement cables are rated at 600 
Vrms max. For measuring voltages greater than 600 Vrms, potential transformers (PTs) 
must be used. 
Contents: The voltage measurement cables are shown on page 2-5 (positioned relative 
to their actual use). A cable set consists of six, 6-foot channel measurement cable 
assemblies (probes), each with a detachable, alligator jaw, safety clip assembly 
(maximum jaw opening, 3/4 in (20 mm)). The safety clip assemblies are red (+) and 
black (-) for each of the four channels. One cable each of red (channel A), yellow 
(channel B), blue (channel C), and grey (channel D), and two each of white are 
provided. 
A pouch for storage of the cables and the AC adapter/battery charger is included in the 
contents of the measurement cable set, but is not shown in the figure.
Optional fused 
voltage adapter
There are two optional fuse accessory kits available for use with the measurement 
cables. One kit (P/N FVA-1) contains one fused voltage adapter and one measurement 
connecting Red cable 50 cm in length. The other kit (P/N FVA-4) contains four voltage 
adapters and four measurement connecting cables 50 cm in length (one Red, one 
Yellow, one Blue, and one Grey).
The single fuse voltage adapter kit is used for one single voltage measurement input. 
While the four fuse voltage adapter kit is used for a three phase and neutral voltage 
measurement inputs.
Continued on next page