REMOTE INTERFACE 
97 
Square 
0.1Hz 
25MHz* 
Ramp 
0.1Hz 
1MHz 
Noise 
Not applicable 
Not applicable 
User (ARB) 
0.1Hz 
20MHz 
*The AFG-2005/2105 is limited to 5MHz, the AFG-
2012/2112 is limited to 12MHz. 
Output 
Amplitude 
When setting the amplitude, MINimum, 
MAXimum and DEFault can be used instead of 
specifying an amplitude. The range depends on 
the function being used. The default amplitude for 
all functions is 100 mVpp (into 50Ω). 
 
Vrms, dBm or Vpp units can be used to specify the 
output units to use with the current command. 
Note, however, that the VOLT:UNIT command 
can be used to set the default units (Vrms, dBm, 
Vpp) for all commands. This will be applicable to 
the Apply command when no unit is specified. The 
unit default is set to Vpp.  
 
The output amplitude can be affected by the 
function and unit chosen. Vpp and Vrms or dBm 
values may have different maximum values due to 
differences such as crest factor. For example, a 
5Vrms square wave will be adjusted to 3.536 Vrms 
for a sine wave.  
DC Offset voltage 
The offset parameter can be set to MINimum, 
MAXimum or DEFault instead of a specified DC 
offset value. The default DC offset is 0 volts.  
 
The maximum and minimum DC offset is limited 
by the output amplitude as shown below. 
|Voffset| < Vmax – Vpp/2