MD 9030 TRMS Electrical & Electronic DMM with Temperature 
Specification 
 
15 
CMRR:>60dB @ DC TO 60Hz, RS=1k
 
Input Impedance: 10M
, 30pF nominal 
(1000M
 for 400.0mV range) 
*Selection by RANGE button manually, and is specified from AC 10mV (AC 40mV for 
True RMS model MD 9030) and up 
 
 
DC Current 
RANGE Accuracy 
 
Burden 
Voltage 
400.0
A 
2.0% + 5d 
0.15mV/
A 
4000
A 
1.2% + 3d 
0.15mV/
A 
40.00mA 
2.0% + 5d 
3.3mV/mA 
400.0mA 
1.2% + 3d 
3.3mV/mA 
4.000A 
2.0% + 5d 
0.03V/A 
10.00A* 
1.2% + 3d 
0.03V/A 
*10A continuous, 20A for 30 second max with 5 minutes cool down interval 
 
AC Current 
RANGE Accuracy 
1)
 Burden 
Voltage 
50Hz -- 500Hz 
400.0
A 
2.0% + 6d 
0.15mV/
A 
4000
A 
1.5% + 4d 
0.15mV/
A 
40.00mA 
2.0% + 6d 
3.3mV/mA 
400.0mA 
1.7% + 4d 
3.3mV/mA 
4.000A 
2.0% + 6d 
0.03V/A 
10.00A* 
1.8% + 4d 
0.03V/A 
*10A continuous, 20A for 30 second max with 5 minutes cool down interval 
 
Diode Tester 
Open Circuit Voltage  Test Current 
(Typical) 
< 1.6 VDC 
0.25mA  
 
Type-K Temperature  
RANGE Accuracy* 
-20
 O
C TO 300 
O
C 2%
 
+ 3
 O
-4
 O
F TO 572 
O
F 2%
 
+ 6
 O
*Type-K thermocouple range & accuracy not included 
 
Audible Continuity Tester 
Audible threshold : between 10