MD 9010 General Purpose Auto – Check Digitalmultimeter Specification 
 
10 
6 Specification 
 
GENERAL SPECIFICATIONS 
 
Display & Update Rate:    
3-5/6 digits 6000 counts; Updates 5 per second nominal 
 
Operating Temperature:
   
0
o
C ~ 40
o
 
Relative Humidity: 
Maximum relative humidity 80% for temperature up to 31
o
C decreasing linearly to 
50% relative humidity at 40
o
 
Altitude:  
 
 
Operating below 2000m 
 
Storage Temperature:    
-20
o
C ~ 60
o
C, < 80% R.H. (with battery removed)  
 
Temperature Coefficient:  
Nominal 0.15 x (specified accuracy)/ 
o
C @ (0
o
C ~ 18
o
C or 28
o
C ~ 40
o
C), or 
otherwise specified 
 
Sensing:
  
 
 
Average sensing  
 
Pollution Degree:
  
 
 
Safety:
    
 
 
Meets IEC61010-1, UL61010B-1, CAN/CSA-C22.2 No. 1010.1-92 
 
Transient Protection:
  
 
4kV lightning surge (1.2/50
s) 
 
Measurement Category:   
CAT II 600V and CAT III 300V  
 
E.M.C.:
  
Meets EN61326 (1997, 1998/A1), EN61000- 4-2 (1995), & EN61000-4-3 (1996) 
 
In an RF Field of 3V/m: 
 
Capacitance function is not specified 
 
Other function ranges:  
 
Total accuracy = Specified accuracy + 45d 
 
Performance above 3V/m is not specified 
 
Overload Protection: 
 
600VDC & VAC rms  
 
Low Battery:
  
 
 
Below approx. 2.4V 
 
Power Supply:
    
 
3V standard button battery x 1 (IEC-CR2032; ANSI-NEDA-5004LC) 
 
Power Consumption (typical):  
6mA for Voltage functions on Auto-V
 position, and 2mA for other functions 
 
APO Consumption (typical):
  
2.2
A  
 
APO Timing:  
 
 
Idle for 3 minutes 
 
Dimension / Weight:
  
 
L113mm x W53mm x H10.2mm / Approx. 78 gm 
 
Special Features: 
 
AutoCheck
TM
 (Automatic V & 
 Selection), and EF-Detection 
 
Accessories:
  
 
 
Battery installed, and User’s manual 
Electrical Specification 
Accuracy is given as +/- (% of reading digits + number of digits) or otherwise specified @ 23
o
C +/- 5
o
and less than 75% R.H.