Voltcraft VC-890 OLED DMM Digital Multimeter with Software included CAT IV 600V, CAT III 1000V VC890 OLED Guía De Información

Los códigos de productos
VC890 OLED
Descargar
Página de 13
 
3.2
 
    Live Data 
For the Live Data message, the payload of the message contain the corresponding values with the current measurement 
mode  of  the  DMM,  where  it  can  be  separated  into  DMM  Function,  Display  1,  Display  2,  Display  3,  Display 
4,Display5,Display6and Status.    The message format is shown as in the following table. 
 
Header 
Length 
Msg 
Type 
DMM 
Functio
n   
Display 
Display2 
Display 
Display 
 
Display 
 
Second 
freque
ncy 
Unit 
Display 
 
Display 
Bar 
Status 
 
Check 
Sum 
2 Byte 
1 Byte 
1 Byte 
2 Byte 
7 Byte 
8 Byte 
10 Byte 
8 Byte 
8 Byte 
3 Byte 
4 Byte 
7 Byte 
2 Byte 
Msg[0]- 
Msg[1] 
Msg[2] 
Msg[3] 
Msg[4]- 
Msg[5] 
Msg[6]- 
Msg[12] 
Msg[13]
-Msg[20
Msg[21]
-Msg[30
Msg[31]
-Msg[38
Msg[39]
-Msg[46
Msg[47
]-Msg[4
9] 
Msg[50]
-Msg[53
Msg[54]
-Msg[55
Msg[56]
-Msg[63
Msg[64]
-Msg[65
 
DMM Function: Msg[4] – Msg[5] 
Two byte  is  used  to  represent  the selected  measurement  mode  (Msg[4])  and  the measurement  range  (Msg[5])  of the 
DMM.    All the available measurement mode of the VC890 DMM is listed at the following:   
Msg[4]: 
Value (HEX) 
Measurement Mode 
0x00   
ACV 
0x01   
Low-Pass Filter 
0x02   
DCV 
0x03   
ACV+DCV 
0x04   
DCmV   
0x05   
Frequency 
0x06   
Duty Cycle   
0x07   
Resistance   
0x08   
Short-Circuit Test 
0x09   
Diode 
0x0A   
Capacitance   
0x0B   
Celsius 
0x0C   
Fahrenheit 
0x0D   
DCuA 
0x0E   
ACuA 
 
0x0F   
DCmA   
0x10   
ACmA 
0x11   
DCA 
0x12   
ACA 
 
The DMM range can be decode at the HEX value at Msg[5], this single byte vale represents the select range of operation