e)  HOLD function
•  With the HOLD function, the current measurement value is shown on the display and the 
measurement process is put on hold.
•  Enable the function by pressing the HOLD/  button. Press the button again to disable to 
the function.
•  <   > appears on the display when the function is enabled.
•  You can continue measuring after you have disabled the function.
f)  Recording minimum and maximum values
•  With the minimum/maximum value function, minimum and maximum values can be 
registered and displayed on the LCD display.
•  Enable the function by pressing the MAX/MIN button (3). Disable the function by pressing 
the MAX/MIN button for approximately 2 seconds. The values on the display disappear.
•  Minimum value: To display minimum values, keep pressing the MAX/MIN button until 
MIN > appears on the LCD display.
•  Maximum value: To display maximum values, keep pressing the MAX/MIN button until 
MAX > appears on the LCD display.
•  Difference: If you wish to view the difference between the maximum and the minimum 
values, keep pressing the MAX/MIN button until < MAXMIN > appears on the LCD display.
g)  REL function
•  The REL function allows you to take a benchmark measurement to avoid potential line 
losses. The current display value is set to zero and saved as a new benchmark value.
•  Press the REL button (6) to enable the function. < REL > appears on the display. Press 
the REL button again to turn the function off. < REL > disappears from the display. The 
benchmark value is reset when the function is turned off.
•  The LCD display shows the measured deviations from the benchmark value.