damaged. 
4.  Take reading from the display 
  Figure 3-4  Frequency and Period Measurements 
Input Impedance =1.1 
MΩ in parallel with 100 pF 
CAUTION:  Maximum Input = 750 V RMS or 1000 V peak, 3x10
V-Hz 
3.6    Measuring Continuity 
Under  continuity  test, when  200 
Ω  range  is selected, the  multimeter alerts you with a beep  when a 
reading is below a threshold resistance level of 10 
Ω. For other ranges, the beeper will sound if a reading 
is below a threshold resistance level listed in table 3-1.  This beep will sound within less than half a 
second when reading measured is below the threshold. 
   
 
 
 
 
     Table 3-1 Threshold resistance levels in Continuity Test 
Model 2831E 
Measuring range 
Beeper on 
200.00 
Ω 
<10 
Ω 
2.0000 k
Ω 
<100 
Ω 
20.000 k
Ω 
<1 
kΩ 
200.00 k
Ω 
<10 
kΩ 
2.0000 
MΩ 
<100 
kΩ 
20.000 
MΩ 
<1 
MΩ 
Model 5491B 
Measuring range 
Beeper on 
500.00 
Ω 
<10 
Ω 
5.0000 k
Ω 
<100 
Ω 
50.000 k
Ω 
<1 
kΩ 
500.00 k
Ω 
<10 
kΩ 
5.0000 M
Ω 
<100 
kΩ 
50.000 
MΩ 
<1 
MΩ 
AC VOLTAGE SOURCE