meas:lmtline? 
Returns the limit line table data. Need to specify 0 (low limit 
line), 1(high limit line) / limit line points. 
Example: meas:lmtline:edit_0? Returns: 3,100,0,110,3,120,2 
(low limit line, 3 points, 100MHz/0dB, 110MHz/3dB, 
120MHz/2dB) 
meas:lmtline:edit 
Sets the limit line table data. Need to specify 0 (low limit 
line), 1(high limit line) / limit line points. 
Example: meas:lmtline:edit_0_CR_3,100,−2,110,−3,120,−2 
(low limit line, 3 points, 100MHz/−2dB, 
110MHz/−3dB,120MHz/−2dB) 
meas:lmtline:edit: 
delall 
Delete all points in limit line table. 
Parameter: 0 (low limit line), 1(high limit line) 
Example: meas:lmtline:edit:delall_0 (delete low lline table) 
BW 
 
con:rbw:auto 
Sets RBW to auto. 
con:rbw? 
Returns the RBW (resolution bandwidth). 
Parameter: 0 (200Hz), 1 (300Hz), 2 (3kHz), 3 (9kHz), 4 
(30kHz), 5 (120kHz), 6 (300kHz), 7 (4MHz) 
con:rbw:man 
Selects the RBW. Parameter: 0 (200Hz), 1 (300Hz), 2 (3kHz), 
3 (9kHz), 4 (30kHz), 5 (120kHz), 6 (300kHz), 7 (4MHz) 
Example: con:rbw:man_1 (sets RBW to 300Hz) 
con:rbw:mode? 
Returns RBW mode. Parameter: auto, manual 
con:vbw:auto 
Sets VBW to auto. 
con:vbw? 
Returns the VBW. Parameter: 0 (10Hz), 1 (30Hz), 2 (100kHz), 
3 (300kHz), 4 (1kHz), 5 (3kHz), 6 (10kHz), 7 (30kHz), 8 
(100kHz), 9 (300kHz), 10 (1MHz) 
con:vbw:man 
Selects the VBW. Parameter: 0 (10Hz), 1 (30Hz), 2 (100Hz), 3 
(300Hz), 4 (1kHz), 5 (3kHz), 6 (10kHz), 7 (30kHz), 8 
(100kHz), 9 (300kHz), 10 (1MHz) 
Example: con:vbw:man_4 (sets VBW to 1kHz) 
con:vbw:mode? 
Returns VBW mode. Parameter: auto, manual 
con:swt:auto 
Sets the sweep time to auto. 
con:swt:man 
Sets the sweep time in msec. 
Example: con:swp:man_5 (sets the sweep time to 5ms) 
con:swt? 
Returns the sweep time in msec. 
con:swt:mode? 
Returns the sweep time mode. Parameter: auto, manual 
con:allcouple 
Sets the RBW, VBW, and sweep time to auto. 
Trigger 
 
con:trig:freerun 
Sets the trigger to free run mode. 
con:trig:video 
Sets the trigger to video and sets the trigger level in current 
unit. Example: con:trig:video_−20 (video mode, −20dBm)