Analog Devices ADP5024 Evaluation Board ADP5024CP-EVALZ ADP5024CP-EVALZ Hoja De Datos

Los códigos de productos
ADP5024CP-EVALZ
Descargar
Página de 28
Data Sheet 
ADP5024 
 
Rev. E | Page 19 of 28 
BUCK1 AND BUCK2 
The buck uses a fixed frequency and high speed current  
mode architecture. The buck operates with an input voltage  
of 2.3 V to 5.5 V.  
The buck output voltage is set through external resistor 
dividers, shown in Figure 47 for BUCK1. The output voltage 
can optionally be factory programmed to default values, as 
indicated in the Ordering Guide section. In this event, R1 and 
R2 are not needed, and FB1 can remain unconnected. In all cases, 
VOUT1 must be connected to the output capacitor. FB1 is 0.5 V. 
BUCK
AGND
FB1
SW1
R1
R2
VOUT1
VOUT1
VIN1
L1
1µH
C5
10µF
V
OUT1
 = V
FB1
+ 1
R1
R2
09888-
047
 
Figure 47. BUCK1 External Output Voltage Setting 
Control Scheme 
The bucks operate with a fixed frequency, current mode PWM 
control architecture at medium to high loads for high efficiency, 
but shift to a power save mode (PSM) control scheme at light 
loads to lower the regulation power losses. When operating in 
fixed frequency PWM mode, the duty cycle of the integrated 
switches is adjusted and regulates the output voltage. When 
operating in PSM at light loads, the output voltage is controlled 
in a hysteretic manner, with higher output voltage ripple. During 
part of this time, the converter is able to stop switching and 
enters an idle mode, which improves conversion efficiency. 
PWM Mode 
In PWM mode, the bucks operate at a fixed frequency of 3 MHz, 
set by an internal oscillator. At the start of each oscillator cycle, 
the PFET switch is turned on, sending a positive voltage across 
the inductor. Current in the inductor increases until the current 
sense signal crosses the peak inductor current threshold, which 
turns off the PFET switch and turns on the nFET synchronous 
rectifier. This sends a negative voltage across the inductor, 
causing the inductor current to decrease. The synchronous 
rectifier stays on for the remainder of the cycle. The buck 
regulates the output voltage by adjusting the peak inductor 
current threshold. 
Power Save Mode (PSM) 
The bucks smoothly transition to PSM operation when the load 
current decreases below the PSM current threshold. When 
either of the bucks enters PSM, an offset is induced in the PWM 
regulation level, which makes the output voltage rise. When the 
output voltage reaches a level approximately 1.5% above the 
PWM regulation level, PWM operation is turned off. At this 
point, both power switches are off, and the buck enters an idle 
mode. The output capacitor discharges until the output voltage 
falls to the PWM regulation voltage, at which point the device 
drives the inductor to make the output voltage rise again to the 
upper threshold. This process is repeated while the load current 
is below the PSM current threshold. 
Th
 has a dedicated MODE pin controlling the PSM 
and PWM operation. A logic level high applied to the MODE 
pin forces both bucks to operate in PWM mode. A logic level 
low sets the bucks to operate in automatic PSM/PWM.  
PSM Current Threshold 
The PSM current threshold is set to100 mA. The bucks employ 
a scheme that enables this current to remain accurately controlled, 
independent of input and output voltage levels. This scheme 
also ensures that there is very little hysteresis between the PSM 
current threshold for entry to and exit from the PSM. The PSM 
current threshold is optimized for excellent efficiency over all 
load currents. 
Oscillator/Phasing of Inductor Switching 
Th
 ensures that both bucks operate at the same 
switching frequency when both bucks are in PWM mode. 
Additionally, th
 ensures that when both bucks are in 
PWM mode, they operate out of phase, whereby the Buck2 
PFET starts conducting exactly half a clock period  after the 
BUCK1 PFET starts conducting. 
Short-Circuit Protection 
The bucks include frequency foldback to prevent output current 
runaway on a hard short. When the voltage at the feedback pin 
falls below half the target output voltage, indicating the possi-
bility of a hard short at the output, the switching frequency is 
reduced to half the internal oscillator frequency. The reduction 
in the switching frequency allows more time for the inductor to 
discharge, preventing a runaway of output current. 
Soft Start 
The bucks have an internal soft start function that ramps the 
output voltage in a controlled manner upon startup, thereby 
limiting the inrush current. This prevents possible input voltage 
drops when a battery or a high impedance power source is 
connected to the input of the converter. 
Current Limit 
Each buck has protection circuitry to limit the amount of 
positive current flowing through the PFET switch and the 
amount of negative current flowing through the synchronous 
rectifier. The positive current limit on the power switch limits 
the amount of current that can flow from the input to the 
output. The negative current limit prevents the inductor  
current from reversing direction and flowing out of the load. 
100% Duty Operation 
With a drop in input voltage, or with an increase in load 
current, the buck may reach a limit where, even with the PFET 
switch on 100% of the time, the output voltage drops below the