Rev. B | Page 6 of 48 
Clock Circuitry 
The default clock input circuit that is populated on the 
 evaluation boards uses a simple transformer-coupled 
circuit using a high bandwidth 1:1 impedance ratio transformer 
(T503) that adds a very low amount of jitter to the clock path. 
The clock input is 50 Ω terminated and ac-coupled to handle 
single-ended sine wave types of inputs. The transformer converts 
the single-ended input to a differential signal that is clipped by 
CR503 before entering the ADC clock inputs.  
The board is set by default to use an external clock generator. 
An external clock source capable of driving a 50 Ω terminated 
input should be connected to J702.  
A differential LVPECL clock driver output can also be used to 
clock the ADC input using th
 (U501). To place the 
 into the clock path, populate R541 and R542 with 0 Ω 
resistors and remove R522 and R523 to disconnect the default 
clock path outputs. In addition, populate R533 and R534 with 
0 Ω resistors. Next, place Y501, which is the Epson Toyocom 
voltage controlled oscillator that serves as the VCXO for the 
. By completing these connections, OUT2 of the 
is connected to the sampling clock inputs of th
The 
 must be configured through the SPI controller 
software to set up the PLL and other operation modes. Consult 
the 
 data sheet for more information about these and 
other options.  
An additional clocking option is provided on the 
evaluation board. In place of connecting an external source for 
the clock, Y502 a low jitter Valpey Fisher clock oscillator can be 
placed and used as the clock source. If using Y502, a jumper 
must be placed on Header P501. 
PDWN 
To enable the power-down feature, add a shorting jumper across 
P101 at Pin 1 and Pin 2 to connect the PDWN pin to AVDD. 
Switching Power Supply 
The ADC on th
 evaluation board can be configured to 
use th
 dual switching power supply to provide power to 
the DRVDD and AVDD rails of the ADC. To configure the board 
to operate from the 
, the following changes must be 
incorporated (see the 
Artwork and Bill of Materials sections for specific recommenda-
tions for part values):  
1.  Install R204 and R221 to enable the 
2.  Install R216 and R218. 
3.  Install L201 and L202. 
4.  Remove JP201 and JP203 and install JP202 and JP204. 
5.  Remove E205 and E207 and install E208 and E209. 
The ADC on th
 evaluation board can be configured 
to use th
 switching power supply to provide power 
to the DRVDD and AVDD rails of the ADC. To configure the 
board to operate from th
, the following changes 
must be incorporated (see th
 Evaluation Board 
Schematics and Artwork and Bill of Materials sections for 
specific recommendations for part values): 
1.  Install R204 to enable th
. 
2.  Install L201 and L202. 
3.  Remove JP201 and JP203 and install JP202 and JP204. 
4.  Remove E205 and E207 and install E208 and E209. 
Making these changes enables the switching converter to power 
the ADC. Using the switching converter as the ADC power source 