Atmel ATSTK500 500 Starter kit and development system. ATSTK500 ATSTK500 Hoja De Datos

Los códigos de productos
ATSTK500
Descargar
Página de 37
 
20 
AVR068 
2591C-AVR-06/06 
Table 5-49. Valid Result Values for the answer to this command 
Values Description 
STATUS_CMD_OK Operation 
succeeded 
STATUS_RDY_BSY_ 
TOUT 
No response from target device within specified timeframe 
5.3.9 CMD_READ_FUSE_PP 
XML PATH: /AVRPART/ICE_SETTINGS/STK500_2/PpReadFuse/ 
Table 5-50. Command format 
Field  
Size 
Values 
Description 
Command ID 
1 byte 
CMD_READ_FUSE_PP 
Command id 
Address 
1 byte 
 
Address of fuse byte to read 
 
Table 5-51. Answer format if command is executed 
Field  
Size 
Values 
Description 
Answer ID 
1 byte 
CMD_ READ_FUSE 
Answer id 
Status 1 
byte 
STATUS_CMD_OK 
 
Data 1 
byte 
 
Data read from device. Contains the 
read low, high or ext fuse byte. Will 
be padded with 0’s if errors 
occurred during read-out. 
5.3.10 CMD_PROGRAM_LOCK_PP 
See CMD_PROGRAM_FUSE. 
Note: 
Address must be sent but is ignored by firmware. 
 
XML PATH: /AVRPART/ICE_SETTINGS/STK500_2/PpProgramLock/ 
5.3.11 CMD_READ_LOCK_PP 
See CMD_READ_FUSE_PP. 
Note: 
Address must be sent but is ignored by firmware. 
 
XML PATH: /AVRPART/ICE_SETTINGS/STK500_2/PpReadLock/ 
5.3.12 CMD_READ_SIGNATURE_PP 
See CMD_READ_FUSE. 
XML PATH: /AVRPART/ICE_SETTINGS/STK500_2/PpReadSign/ 
5.3.13 CMD_READ_OSCCAL_PP 
See CMD_READ_FUSE. 
XML PATH: /AVRPART/ICE_SETTINGS/STK500_2/PpReadOsccal/