AVR068
 
 
21
2591C-AVR-06/06 
5.3.14 CMD_SET_CONTROL_STACK 
Uploads the control stack to the STK.  This is used for both PP and HVSP. 
Note: 
The Control stack must always be uploaded before performing any programming 
commands in high voltage mode if the STK500 has been powered down. 
 
To check if the controller has a valid control stack: Read 
PARAM_CONTROLLER_INIT 
Se chapter 5.7.14:  PARAM_CONTROLLER_INIT 
Table 5-52. Command format 
Field  
Size 
Values 
Description 
Command ID 
1 byte 
CMD_SET_CONTROL_
STACK 
Command id 
Data 
32 bytes 
 
Control stack Data 
 
Table 5-53. Answer format (same for all results) 
Field  
Size 
Values 
Description 
Answer ID 
1 byte 
CMD_SET_CONTROL_
STACK 
Answer id 
Status 1 
byte 
STATUS_CMD_OK 
Result Value indicating the result 
of the operation 
5.4 High Voltage Serial Programming Commands 
This chapter describes the High Voltage Serial Programming (HVSP) commands. 
Note that the SetControlStack command is required for HVSP as for PP. Description 
of the SetControlStack is found in section 5.3.14 under Parallel Programming. 
5.4.1 CMD_ENTER_PROGMODE_HVSP 
This command will make the target device enter programming mode if it succeeds. 
XML path: /AVRPART/ICE_SETTINGS/STK500_2/HvspEnterProgMode/