Atmel SAM4S-XPLD Atmel ATSAM4S-XPLD ATSAM4S-XPLD Hoja De Datos

Los códigos de productos
ATSAM4S-XPLD
Descargar
Página de 1125
 770
SAM4S [DATASHEET]
11100E–ATARM–24-Jul-13
36.6.11.1WAVSEL = 00
When WAVSEL = 00, the value of TC_CV is incremented from 0 to 0xFFFF. Once 0xFFFF has been reached, the value
of TC_CV is reset. Incrementation of TC_CV starts again and the cycle continues. See 
.
An external event trigger or a software trigger can reset the value of TC_CV. It is important to note that the trigger may
occur at any time. See 
RC Compare cannot be programmed to generate a trigger in this configuration. At the same time, RC Compare can stop
the counter clock (CPCSTOP = 1 in TC_CMR) and/or disable the counter clock (CPCDIS = 1 in TC_CMR).
Figure 36-7. WAVSEL= 00 without trigger
Figure 36-8. WAVSEL= 00 with trigger
Time
Counter Value
R
C
R
B
R
A
TIOB
TIOA
Counter cleared by compare match with 0xFFFF
0xFFFF
Waveform Examples
Time
Counter Value
R
C
R
B
R
A
TIOB
TIOA
Counter cleared by compare match with 0xFFFF
0xFFFF
Waveform Examples
Counter cleared by trigger