Atmel SAM4S-XPLD Atmel ATSAM4S-XPLD ATSAM4S-XPLD Hoja De Datos

Los códigos de productos
ATSAM4S-XPLD
Descargar
Página de 1125
 772
SAM4S [DATASHEET]
11100E–ATARM–24-Jul-13
36.6.11.3WAVSEL = 01
When WAVSEL = 01, the value of TC_CV is incremented from 0 to 0xFFFF. Once 0xFFFF is reached, the value of
TC_CV is decremented to 0, then re-incremented to 0xFFFF and so on. See 
A trigger such as an external event or a software trigger can modify TC_CV at any time. If a trigger occurs while TC_CV
is incrementing, TC_CV then decrements. If a trigger is received while TC_CV is decrementing, TC_CV then increments.
See 
.
RC Compare cannot be programmed to generate a trigger in this configuration. 
At the same time, RC Compare can stop the counter clock (CPCSTOP = 1) and/or disable the counter clock (CPCDIS =
1).
Figure 36-11.WAVSEL = 01 Without Trigger
Figure 36-12.WAVSEL = 01 With Trigger
Time
Counter Value
R
C
R
B
R
A
TIOB
TIOA
Counter decremented by compare match with 0xFFFF
0xFFFF
Waveform Examples
Time
Counter Value
TIOB
TIOA
Counter decremented by compare match with 0xFFFF
0xFFFF
Waveform Examples
Counter decremented
by trigger
Counter incremented
by trigger
R
C
R
B
R
A