STMicroelectronics Stepper motor driver mounting the L6474 in high power PowerSO package EVAL6474PD EVAL6474PD Hoja De Datos

Los códigos de productos
EVAL6474PD
Descargar
Página de 52
Programming manual
L6474
46/52
Doc ID 022529 Rev 3
Any attempt to read an inexistent register (wrong address value) causes the command to be 
ignored and the WRONG_CMD flag to rise at the end of command byte, the same is true 
when an unknown command code is sent.
9.2.5 Enable
         
The Enable command turns on the power stage of the device.
When the motor is in high-impedance state, an Enable command forces the bridges to exit 
from high impedance state.
This command can be given anytime and is immediately executed. 
9.2.6 Disable
         
The Disable command immediately disables the power bridges (high-impedance state) and 
raises the HiZ flag.
This command can be given anytime and is immediately executed.
9.2.7 GetStatus
         
The GetStatus command returns the Status register value. The GetStatus command resets 
the STATUS register warning flags. The command forces the system to exit from any error 
state. The GetStatus command DOES NOT reset the HiZ flag.
Table 34.
 HardStop command structure
Bit 
7 Bit 
6 Bit 
5 Bit 
4 Bit 
3 Bit 
2 Bit 
1 Bit 
1 0 1 1 1 0 0 0 from 
host 
Table 35.
Disable command structure
Bit 7 
Bit 6 
Bit 5 
Bit 4 
Bit 3 
Bit 2 
Bit 1 
Bit 0 
0 1 0 1 0 0 0 
from 
host 
Table 36.
GetStatus command structure
Bit 
7 Bit 
6 Bit 
5 Bit 
4 Bit 
3 Bit 
2 Bit 
1 Bit 
1 1 0 1 0 0 0 0 from 
host 
STATUS MSByte 
to host 
STATUS LSByte 
to host