Programming manual
L6474
44/52
Doc ID 022529 Rev 3
Figure 15.
Command with three-byte argument
By default, the device returns an all zeroes response for any received byte, the only 
exceptions are GetParam and GetStatus commands. When one of these commands is 
received, the following response bytes represent the related register value (see 
).
Response length can vary from 1 to 3 bytes.
Figure 16.
Command with three-byte response
During response transmission, new commands can be sent. If a command requiring a 
response is sent before the previous response is completed, the response transmission is 
aborted and the new response is loaded into the output communication buffer (see 
Figure 17.
Command response aborted
When a byte that does not correspond to a command is sent to the IC it is ignored and the 
WRONG_CMD flag in the STATUS register is raised (see 
).
9.2.2 Nop
         
Nothing is performed.
Table 31.
Nop command structure
Bit 
7 Bit 
6 Bit 
5 Bit 
4 Bit 
3 Bit 
2 Bit 
1 Bit 
0 0 0 0 0 0 0 0 From 
host