Siemens MICROMASTER 420 0.25 kW 1-phase frequency inverter, 230 Vac to , 6SE6420-2AB12-5AA1 6SE6420-2AB12-5AA1 Hoja De Datos

Los códigos de productos
6SE6420-2AB12-5AA1
Descargar
Página de 130
International English                                                                                 6. TROUBLESHOOTING
92
MICROMASTER 420 Operating Instructions
6SE6400-5AA00-0BP0
!
Warnings
♦  Repairs on equipment may only be carried out by Siemens Service, by repair
centers authorized by Siemens or by qualified personnel who are thoroughly
acquainted with all the warnings and operating procedures contained in this
manual.
♦  Any defective parts or components must be replaced using parts contained in the
relevant spare parts list.
♦  Disconnect the power supply before opening the equipment for access
6.1 
Troubleshooting with the Status Display Panel
Table 6-1 explains the meaning of the various states of the LEDs on the Status Display
Panel (SDP).
Table 6-1
Inverter conditions indicated by the LEDs on the SDP
LEDs
Green
Yellow
Priority
Display
Inverter Status Definitions
OFF
OFF
1
Mains not present
OFF
ON
8
Inverter fault – other than those
listed below
ON
OFF
13
Inverter running
ON
ON
14
Ready to run – standby
OFF
Flashing – R1
4
Fault – Overcurrent
Flashing – R1
OFF
5
Fault – Overvoltage
Flashing – R1
ON
7
Fault – Motor Overtemperature
ON
Flashing – R1
8
Fault – Inverter Overtemperature
Flashing – R1
Flashing – R1
9
Warning Current Limit (both LEDs
flashing at the same time)
Flashing – R1
Flashing – R1
11
Other warning (both LEDs
alternate flashing)
Flashing – R1
Flashing – R2
6/10
Undervoltage trip/Undervoltage
warning
Flashing – R2
Flashing – R1
12
Inverter is not in ready state –
display >0
Flashing – R2
Flashing – R2
2
ROM failure (both LEDs flashing at
the same time)
Flashing – R2
Flashing – R2
3
RAM failure (both LEDs alternate
flashing)
R1 – On time 900 milliseconds
R2 – On time 300 milliseconds