Panasonic AKT4112100J Temperature Controller KT4 AKT4112100J Hoja De Datos
Los códigos de productos
AKT4112100J
3
3.2 External dimensions (Unit: mm)
(Fig. 3.2-1)
3.3 Panel cutout (Unit: mm)
Lateral close mounting
n: Number of units mounted
Caution: If lateral close mounting is used for the controller,
IP66 specification may be compromised, and all
warranties will be invalidated.
(Fig.
3.3-1)
3.4 CT (Current transformer) external dimensions (Unit: mm)
AKT4815 (for 5A, 10A, 20A)
AKT4816 (for 50A)
(Fig. 3.4-1)
3.5 Mounting
Mount the controller vertically to fulfill the Dust-proof/Drip-proof specification (IP66).
Mountable panel thickness: 1 to 15mm
Insert the controller from the front side of the panel.
Attach the mounting brackets by the holes at the top and bottom of the case and secure the controller
Mountable panel thickness: 1 to 15mm
Insert the controller from the front side of the panel.
Attach the mounting brackets by the holes at the top and bottom of the case and secure the controller
in place with the screws.
(Fig.3.5-1)
4. Wiring
Warning
Turn the power supply to the instrument off before wiring or checking it.
Working or touching the terminal with the power switched on may result in severe
injury or death due to Electric Shock.
Working or touching the terminal with the power switched on may result in severe
injury or death due to Electric Shock.
75
45
+0.5
0
45
+0
.5 0
45
+0
.5 0
n x 48-3
+0.5
0
Warning
As the case is made of resin, do
not use excessive force while
s c r e w i n g i n t h e m o u n t i n g
bracket, or the case or screw
type mounting bracket could be
damaged.
The torque is approximately
0.12N•m.
not use excessive force while
s c r e w i n g i n t h e m o u n t i n g
bracket, or the case or screw
type mounting bracket could be
damaged.
The torque is approximately
0.12N•m.
48
11.5
95
101 (*)
48
44.5
48 (*)
59.7
Gasket A
Screw type mounting bracket
Terminal cover
(*) Terminal cover (AKT4801)