Idec HE9Z-GP15 Hoja De Datos

Descargar
Página de 8
3
HS5D Miniature Interlock Switches
Head removal detection for safer performance.
Specifications
Applicable Standards
ISO14119
EN1088
IEC60947-5-1
EN60947-5-1 (TÜV approval)
GS-ET-15 (TÜV approval)
UL508
CSA C22.2 No. 14
IEC60204-1/EN60204-1  
(applicable standards for use) 
Operating Temperature –30 to +70°C (no freezing)
Relative Humidity
45 to 85% (no condensation)
Storage Temperature –40 to +80°C (no freezing)
Pollution Degree
3
Impulse Withstand 
Voltage
4 kV
Contact Resistance
50 mΩ maximum (initial value)
Insulation Resistance  
(500V DC megger)
Between live and dead metal parts:  
100 MΩ minimum
Between terminals of different poles: 
100 MΩ minimum
Electric Shock  
Protection Class
Class II (IEC61140)
Degree of Protection
IP67 (IEC60529)
Shock Resistance
Damage limits: 1000 m/s
2
Vibration Resistance
Operating extremes:  
10 to 55 Hz, amplitude 0.5 mm 
Damage limits:  
30 Hz, amplitude 1.5 mm
Actuator Operating 
Speed
0.05 to 1.0 m/s
Direct Opening Travel 10 mm minimum
Direct Opening Force 50N minimum
Operating Frequency
900 operations per hour
Mechanical Durability 1,000,000 operations minimum (GS-ET-15)
Electrical Durability
100,000 operations minimum  
     (AC-12 250V, 6A)
1,000,000 operations minimum  
  (24V AC/DC,100 mA)
 (operation frequency: 900 operations per hour)
Performance of  
Terminals 11-12 of 
Removed Head Unit
Mechanical damage limits: 10 operations min. 
Insulation resistance: 100 MΩ  (initial value)
Dielectric strength: 1000V, 1 minute  
 
(initial value)
Conditional  
Short-circuit Current
100A  (250V) (note)
Weight (approx.)
Plastic head: 80g        
Metal head:  110g
Note: Use a 250V/10A fast-blow fuse as a short-circuit protector.
Contact Ratings
Rated Insulation Voltage (Ui) 
300V
Thermal Current (Ith)
10A
Rated Voltage (Ue)
30V
125V
250V
Rated 
Current 
(Ie) *
AC
Resistive load (AC-12) 
10A
10A
6A
Inductive Load (AC-15)
10A
5A
3A
DC
Resistive load (DC-12) 
8A
2.2A
1.1A
Inductive Load (DC-13)
4A
1.1A
0.6A
Minimum applicable load (reference): 5V AC/DC, 1 mA 
• 
(Applicable range may vary with operating conditions and load 
types.)
*
TÜV rating: AC-15 3A/250V, DC-13 4A/30V
Type No. Development
Parts Description
Head removal detection function turns OFF the main circuit 
 
(11-12) when the head of the HS5D is removed.
The HS5D is the same size as 2 contact type interlock 
 
switches (HS5B). 3 contact types with dual enabling con-
tacts and a monitor contact are available. Can be installed 
in narrow spaces. (30W × 30D × 91H mm)
The actuator is interchangeable with HS5B and HS5E.
 
Double insulation structure eliminates the need for ground-
 
ing.
The head orientation can be rotated, allowing 8 different 
 
actuator entries.
Degree of protection (contacts): IP67 (IEC60529)
 
NC contacts with direct opening action (IEC/EN60947-5-1)
 
Proprietary actuators prevent invalidation of the contacts 
 
(ISO14119, EN1088).
M3 terminal screws for easy wiring.
 
Gold-plated co
 
ntacts suitable for small loads.
Right-angle Actuator
(SUS304)
Angle 
Adjustable
Actuator
(for hinged doors)
Right-angle Actuator
w/rubber bushing
Straight Actuator
(SUS304)
Straight Actuator
w/rubber bushing
M3 Terminal Screw
Gland Port
(Use conduits or 
cable glands which 
can maintain IP67 
protection.)
HS5D-11 Z RN M
Circuit Code
11: 1NO-1NC
02: 2NC
12: 1NO-2NC
03: 3NC
Head Material
blank: Plastic
Z : 
Metal
Head/Housing Color
RN:  Red/Gray
Gland Port
blank: G1/2
P: 
PG13.5
M
M20
(100405)