Intel S5500WBR Manual De Usuario

Descargar
Página de 117
Intel® Server Board S5500WB TPS 
Configuration Jumpers 
 
Revision 1.9 
 
Intel order number E53971-008 
47 
Table 17: Server Board Jumpers (J1B5, J1C2, J1C3, J1B4, J6A3, J6A2) 
Jumper Name 
Jumper Position 
Mode of 
Operation 
Note 
J1B5: BMC Force 
Update jumper 
1-2 
Normal 
IBMC GPIO[1] is pulled HIGH. Default position. 
2-3 
Update 
IBMC GPIO[1] is pulled LOW. 
J1C2: Password Clear 
 
1-2 
Normal 
ICH10R INTRUDER# pin is pulled HIGH. Default 
position. 
2-3 
Clear Password 
ICH10R INTRUDER# pin is pulled LOW. 
J1C3: BIOS Recovery 
Mode 
 
1-2 
Normal 
ICH10R GPIO [55] is pulled HIGH. Default 
position. 
2-3 
Recovery 
ICH10R GPIO [55] is pulled LOW. 
J1B4: CMOS Clear 
 
1-2 
Normal 
ICH10R RTCRST# pin is pulled HIGH. Default 
position. 
2-3 
Clear CMOS 
Settings 
ICH10R RTCRST# pin is pulled LOW. 
J6A3: Video Master 
 
1-2 
Internal 
Internal connector will override if both connectors 
are used. 
2-3 
External 
External connector will override if both 
connectors are used. 
J7A2: ME Firmware 
Force Update  
1-2 
Disabled 
 Default 
2-3 
Enabled 
 
J6A2: Serial Interface 
 
– 2 
DCD to DTR 
Data Carrier Detect 
– 4 
DSR to DTR 
Data Set Ready 
 
6.1.1 
Force IBMC Update (J1B5) 
When performing a standard BMC firmware update procedure, the update utility places the 
BMC into an update mode, allowing the firmware to load safely onto the flash device. In the 
unlikely event the BMC firmware update process fails due to the BMC not being in the proper 
update state, the server board provides a BMC Force Update jumper (J1B5) which will force the 
BMC into the proper update state. The following procedure should be followed in the event the 
standard BMC firmware update process fails.  
Table 18. Force IBMC Update Jumper 
Jumper Position 
Mode of 
Operation 
Note 
1-2 
Normal 
IBMC GPIO[1] is pulled HIGH. Default position. 
2-3 
Update 
IBMC GPIO[1] is pulled LOW. 
 
1.  Power down and remove the AC power cord.  
2.  Open the server chassis. See your server chassis documentation for instructions.  
3.  Move jumper from the default operating position, covering pins1 and 2, to the enabled 
position, covering pins 2 and 3.  
4.  Close the server chassis.  
5.  Reconnect the AC cord and power up the server.