Intel S5500WBR Manual De Usuario

Descargar
Página de 117
Configuration Jumpers 
Intel® Server Board S5500WB TPS 
 
 
Revision 1.9 
Intel order number E53971-008 
48 
6.  Perform the BMC firmware update procedure as documented in the README.TXT file 
included in the given BMC firmware update package. After successful completion of the 
firmware update process, the firmware update utility may generate an error stating the 
BMC is still in update mode.  
7.  Power down and remove the AC power cord.  
8.  Open the server chassis.  
9.  Move the jumper from the enabled position, covering pins 2 and 3 to the disabled 
position, covering pins 1 and 2.  
10. Close the server chassis.  
11. Reconnect the AC cord and power up the server. 
Note: Normal BMC functionality is disabled with the Force BMC Update jumper is set to the 
enabled position. You should never run the server with the BMC Force Update jumper set in 
this position. You should only use this jumper setting when the standard firmware update 
process fails. This jumper should remain in the default / disabled position when the server is 
running normally. 
The server board has several 3-pin jumper blocks that can be used to configure, protect, or 
recover specific features of the server board.  
6.1.2 
Password Clear (J1C2) 
The user sets this 3-pin jumper to clear the password.  
Table 19. Password Clear Jumper 
Jumper 
Position 
Mode of Operation 
Note 
1-2 
Normal 
ICH10R INTRUDER# pin is pulled HIGH. Default position. 
2-3 
Clear Password 
ICH10R INTRUDER# pin is pulled LOW. 
 
6.1.2.1 
Clearing the Password  
1. Power down server. Do not unplug the power cord.  
2. Open the chassis. For instructions, see your server chassis documentation.  
3. Move jumper (J1B6) from the default operating position, covering pins 1 and 2, to the 
password clear position, covering pins 2 and 3.  
4. Close the server chassis.  
5. Power up the server, wait 10 seconds or POST completes.  
6. Power down the server.  
7. Open the chassis and move the jumper back to default position, covering pins 1 and 2.  
8. Close the server chassis.  
9. Power up the server.  
 
The password is now cleared and you can reset it by going into the BIOS setup.