Intel S5500WBR Manual De Usuario

Descargar
Página de 117
Intel® Server Board S5500WB TPS 
Intel
®
 Light-Guided Diagnostics 
Revision 1.9 
 
 
Intel order number E53971-008 
71 
Table 51. System Status LED 
Color 
State 
System Status 
Description 
Green 
Solid on 
Ok 
System ready 
Green 
~1 Hz blink 
Degraded 
System degraded: 
BIOS detected 
1.  Unable to use all of the installed memory (more than one 
DIMM installed).1 
2.  In a mirrored configuration, when memory mirroring takes 
place and system loses memory redundancy. This is not 
covered by (2). 1 
3.  PCI Express* correctable link errors. 
Integrated BMC detected 
1.  Redundancy loss such as a power supply or fan. Applies 
only if the associated platform subsystem has redundancy 
capabilities. 
2.  CPU disabled 
– if there are two CPUs and one CPU is 
disabled. 
3.  Fan alarm 
– Fan failure. Number of operational fans should 
be more than minimum number needed to cool the system. 
4.  Non-critical threshold crossed 
– Temperature, voltage, 
power nozzle, power gauge, and PROCHOT2 (Therm Ctrl) 
sensors. 
5.  Battery failure.  
6.  Predictive failure when the system has redundant power 
supplies. 
 
Amber 
~1 Hz blink 
Non-Fatal 
Non-fatal alarm 
– system is likely to fail: 
BIOS Detected 
1.  In non-mirroring mode, if the threshold of ten correctable errors 
is crossed within the window.1 
2.  PCI Express* uncorrectable link errors. 
Integrated BMC Detected 
1.  Critical threshold crossed 
– Voltage, temperature, power nozzle, 
power gauge, and PROCHOT (therm Ctrl) sensors. 
2.  VRD Hot asserted. 
3.  The minimum number of fans required to cool the system are 
not present or have failed.