Intel
®
 Light-Guided Diagnostics 
Intel® Server Board S5500WB TPS 
 
 
Revision 1.9 
Intel order number E53971-008 
72 
Color 
State 
System Status 
Description 
Amber 
Solid on 
Fatal 
Fatal alarm 
– system has failed or shut down: 
BIOS Detected 
1.  DIMM failure when there is one DIMM present and no good 
memory is present.1 
2.  Run-time memory uncorrectable error in non-redundant mode.1 
3.  CPU configuration error (for instance, processor stepping 
mismatch). 
Integrated BMC Detected 
1.  CPU IERR signal asserted. 
2.  CPU 1 is missing. 
3.  CPU THERMTRIP. 
4.  No power good 
– power fault. 
5.  Power Unit Redundancy sensor 
– Insufficient resources offset 
(indicates not enough power supplies are present). 
Off 
N/A 
Not ready 
AC power off 
 
Notes: 
1.  The BIOS detects these conditions and sends a Set Fault Indication command to the Integrated BMC to 
provide the contribution to the system status LED.  
2.  Support for an upper, non-critical threshold limit is not provided in default SDR configuration. However if a 
user does enable this threshold in the SDR, then the system status LED should behave as described.