Jumper Blocks 
Intel® Server Board S1400SP TPS 
 
 
Revision 1.0 
Intel order number G64248-001 
94 
5.  Power on system. 
Note: BIOS Error Manager should report a 5220 error code (BIOS Settings reset to default 
settings) 
9.5  BMC Force Update Jumper Block 
The BMC Force Update jumper is used to put the BMC in Boot Recovery mode for a low-level 
update. 
It is used when the BMC has become corrupted and is non-functional, requiring a new BMC 
image to be loaded on to the server board.  
1.  Turn off the system and remove power cords. 
2.  Move the BMC FRC UPDT Jumper from the default (pins 1 and 2) operating position to 
the Force Update position (pins 2 and 3). 
3.  Re-attach system power cords. 
4.  Power on the system. 
Note: System Fans will boost and the BIOS Error Manager should report an 84F3 error code 
(Baseboard Management Controller in update mode). 
5.  Boot to the EFI shell and update the BMC firmware using BMC####.NSH (where #### is 
the version number of the BMC). 
6.  When update has successfully completed, power off system. 
7.  Remove AC power cords. 
8.  Move BMC FRC UPDT jumper back to the default position  
9.  Install AC power cords. 
10. Power on system. 
11. Boot to the EFI shell and update the FRU and SDR data using FRUSDR####.nsh 
(where #### is the version number of the FRUSDR package). 
12. Reboot the system.  
13. Configure desired BMC configuration settings.