Intel S1400SP4 BBS1400SP4 Manuale Utente
Codici prodotto
BBS1400SP4
Jumper Blocks
Intel® Server Board S1400SP TPS
Revision 1.0
Intel order number G64248-001
94
5. Power on system.
Note: BIOS Error Manager should report a 5220 error code (BIOS Settings reset to default
settings)
settings)
9.5 BMC Force Update Jumper Block
The BMC Force Update jumper is used to put the BMC in Boot Recovery mode for a low-level
update.
update.
It is used when the BMC has become corrupted and is non-functional, requiring a new BMC
image to be loaded on to the server board.
image to be loaded on to the server board.
1. Turn off the system and remove power cords.
2. Move the BMC FRC UPDT Jumper from the default (pins 1 and 2) operating position to
2. Move the BMC FRC UPDT Jumper from the default (pins 1 and 2) operating position to
the Force Update position (pins 2 and 3).
3. Re-attach system power cords.
4. Power on the system.
4. Power on the system.
Note: System Fans will boost and the BIOS Error Manager should report an 84F3 error code
(Baseboard Management Controller in update mode).
(Baseboard Management Controller in update mode).
5. Boot to the EFI shell and update the BMC firmware using BMC####.NSH (where #### is
the version number of the BMC).
6. When update has successfully completed, power off system.
7. Remove AC power cords.
8. Move BMC FRC UPDT jumper back to the default position
9. Install AC power cords.
10. Power on system.
11. Boot to the EFI shell and update the FRU and SDR data using FRUSDR####.nsh
7. Remove AC power cords.
8. Move BMC FRC UPDT jumper back to the default position
9. Install AC power cords.
10. Power on system.
11. Boot to the EFI shell and update the FRU and SDR data using FRUSDR####.nsh
(where #### is the version number of the FRUSDR package).
12. Reboot the system.
13. Configure desired BMC configuration settings.
13. Configure desired BMC configuration settings.