1.8.  Specifications 
 
Measurement (Based on Installed Sensors) 
Display Range 
Oxygen 
0.1 to 20.9% 
Stack Temperature 
-4 to 2,192 °F (-20 to 1,200 °C) 
Primary/Ambient Air Temperature 
-4 to 999 °F (-20 to 537 °C) 
Carbon Monoxide (CO) (H
2
 compensated) 
0 to 4,000 ppm 
Pressure/Draft 
±72” H
2
O (±179 mb) 
CO High Range 
4,001 to 20,000 ppm 
Nitric Oxide (NO) 
0 to 3,000 ppm 
Nitrogen Dioxide (NO
2
0 to 500 ppm 
Sulfur Dioxide (SO
2
0 to 5,000 ppm 
 
 
 
Calculated Value (Based on Installed Sensors) 
Display Range 
Combustion Efficiency 
0.1 to 100% 
Excess Air 
1 to 250% 
Carbon Dioxide (dry basis) 
0.1 to fuel-dependent max in % 
NO
x
 (NO
x
 = NO + NO
2
0 to 3,500 ppm 
NO
x
 referenced to %O
2
 
0 to 9,999 ppm 
CO referenced to %O
2
 
0 to 9,999 ppm 
NO referenced to %O
2
 
0 to 9,999 ppm 
NO
2
 referenced to %O
2
 
0 to 9,999 ppm 
SO
2
 referenced to %O
2
 
0 to 9,999 ppm 
 
 
 
 
 
NOTE:  Calculations are performed only when the measured 
oxygen level is below 16.0% and the stack temperature is below 
2,000 °F (1,093 °C).