ppuconfig (1M) Manpage
ppuconfig (1M)
NAME
ppuconfig – configure Pay Per Use daemon
SYNOPSIS
Path:
/usr/sbin
ppuconfig [-m meter] [-p proxy[:port]] [-s system_id|-h] [-u]
ppuconfig -t
DESCRIPTION
ppuconfig
is a tool for configuring communication between the Pay Per
Use daemon
ppud
(see ppud(1M)) and a utility meter. A utility meter
must be specified for a Pay Per Use system before the
ppud
daemon will
collect and send utilization data to HP. In the absence of this data, HP
may assume 100% utilization and bill for the system accordingly.
may assume 100% utilization and bill for the system accordingly.
If
ppuconfig
is invoked without any options the current settings will be
displayed.
If this is the first time you are supplying utility meter configuration
information, after specifying the utility meter with the
information, after specifying the utility meter with the
ppuconfig
command, it is recommended to execute
ppuconfig -t
to perform a
round trip communication test. If the test is successful, verify the
ppud
daemon is running using the
ps
command.
When
ppuconfig
is used to modify the configuration information related
to the utility meter, it is not necessary to restart a running
ppud
daemon.
When configuration information is modified it is recommended that
ppuconfig -t
is executed to verify the new configuration.