HP B.06.X ユーザーズマニュアル

ページ / 78
PPU Manpages
ppuconfig (1M) Manpage
Appendix D
73
ppuconfig (1M) Manpage
ppuconfig (1M)
NAME
ppuconfig – configure Pay Per Use daemon
SYNOPSIS
Path: 
/usr/sbin
ppuconfig [-m meter] [-p proxy[:port]] [-s system_id|-h] [-u]
ppuconfig -t
DESCRIPTION
ppuconfig
 is a tool for configuring communication between the Pay Per 
Use daemon 
ppud
 (see ppud(1M)) and a utility meter. A utility meter 
must be specified for a Pay Per Use system before the 
ppud
 daemon will 
collect and send utilization data to HP. In the absence of this data, HP 
may assume 100% utilization and bill for the system accordingly.
If 
ppuconfig 
is invoked without any options the current settings will be 
displayed.
If this is the first time you are supplying utility meter configuration 
information, after specifying the utility meter with the 
ppuconfig 
command, it is recommended to execute 
ppuconfig -t
 to perform a 
round trip communication test. If the test is successful, verify the 
ppud
 
daemon is running using the 
ps 
command.
When 
ppuconfig
 is used to modify the configuration information related 
to the utility meter, it is not necessary to restart a running 
ppud
 daemon. 
When configuration information is modified it is recommended that 
ppuconfig -t
 is executed to verify the new configuration.