4)  Select  Energy  Management  Recovery  OFF  or  ON  –
Energy Management Recovery (EMR) causes the thermostat
to start heating or cooling early to make the building tem-
perature reach the program setpoint at the time you specify.
Heating will start 5 minutes early for every 1° of temperature
required  to  reach  setpoint.  Cooling  allows  more  time  per
degree because it takes longer to reach temperature.
Example: You select EMR and have your heating programmed
to 65° at night and 70° at 7 AM. If the building temperature
is 65° the difference between 65° and 70° is 5°. Allowing 5
minutes per degree the thermostat setpoint will change to
70° at 6:35 AM.
5)  Select filter replacement run time - The thermostat will
display
“FLTR” after a set time of operation. This is a reminder
to change or clean your air filter. This time can be set from
0 to 1950 hours in 50 hour increments.
A selection of 000 
will cancel this feature. When “FLTR” is displayed, you
can clear it by pressing HOLD and RUN at the same time.
This resets the timer and starts counting the hours until the
next filter change. Changing the time in the menu also resets
the timer.
6)  Select Compressor Lockout LOC OFF or ON - Selecting
LOC ON will cause the thermostat to wait 5 minutes before
turning on the compressor if the heating and cooling system
loses power. It will also wait 5 minutes minimum between
cooling cycles. This is intended to help protect the compres-
sor from short cycling. Some newer compressors already
have a time delay built in and do not require this feature.
Your compressor manufacturer can tell you if the feature is
already present in their system. When the compressor time
delay occurs it will flash the (snowflake icon) for about five
minutes then turn on the compressor.
7)  Select Temperature Display Adjustment 4 LO to 4 HI - Al-
lows you to adjust the room temperature display 4° higher or
lower. Your thermostat was accurately calibrated at the factory
but you have the option to change the display temperature
to match your previous thermostat.
8)  Select F° or C° Readout - Changes the display readout to
Centigrade or Fahrenheit as required.
OPERATING FEATURES
Now that you are familiar with the thermostat buttons and display,
read the following information to learn about the many features
of the thermostat.
SIMULTANEOUS HEATING/COOLING PROGRAM STOR-
AGE  
—  When  programming,  you  can  enter  both  your
heating and cooling programs at the same time. There is
no need to reprogram the thermostat at the beginning of
each season.
TEMPERATURE OVERRIDE — Press
or
until the
display shows the temperature you want. The thermostat
will override current programming and keep the room tem-
perature at the selected temperature until the next program
period begins. Then the thermostat will automatically revert
to the program.
HOLD TEMPERATURE — The thermostat can hold any
temperature within its range for an indefinite period without
reverting to the programmed temperature. Momentarily press
HOLD button.
“HOLD” will be displayed. Then choose the
desired temperature by pressing
or
. The thermostat
will hold the room temperature at the selected setting until
you press RUN button to start program operation again.
CONFIGURATION  MENU  —  Allows  you  to  customize
certain thermostat options.
PROGRAMMING YOUR THERMOSTAT
This  section  will  help  you  plan  your  thermostat’s  program  to
meet your needs. For maximum comfort and efficiency, keep the
following guidelines in mind when planning your program.
 •  When  heating  (cooling)  your  building,  program  the
   temperatures to be cooler (warmer) when the building is
   vacant or during periods of low activity.
 •  During  early  morning  hours,  the  need  for  cooling  is
   usually minimal.
1
Step
Press Button(s)
Displayed (Factory Default)
Press          or          to select:           
COMMENTS
HOLD
(0:00)
0 to 8 hrs (in 
15 minute increments)
2
(FA)
SL
Select temporary Hold time
4
5
E
(ON)
OFF
6
7
 LOC
(OFF)
ON
0 HI
(0)
4 LO to
4 HI
(F)
C
Returns to normal operation
8
9
Select Energy Management Recovery OFF or ON
Select compressor lockout OFF or ON
Select temperature display adjustment higher or lower
Select temperature display to  F or  C
RUN
PRGM
and
 RUN
HOLD*
HOLD*
3
d-L
(ON)
OFF
Select display backlight OFF or ON
HOLD*
HOLD*
Filter
(000)
0 to 1950 hours
(in 50 hour increments)
Select filter replacement run time
HOLD*
HOLD*
HOLD*
Select FA or SL (Fast or Slow) heating cycle rate
Configuration Menu
* Press 
HOLD to advance to next item or TIME to move backwards to previous item
 