Wall Hanging Installation 
 
For a wall mount installation, use TK-BK01 
brackets to securely attach the T-K2 to the 
wall.  
Locate the heater as desired, but follow all 
applicable local codes, as well as the indoor or 
outdoor clearances that apply to the 
installation. 
 
Standing Installation 
 
If the unit is to be installed standing on a 
surface, adjust the legs so that the unit stands 
securely and is level (legs can be adjusted up 
to 1”).  
Do not install the unit standing directly on a 
combustible surface.  Use a 3” non-
combustible base. 
 
Use the included L brackets to connect the 
unit to a wall to ensure that it does not fall over.  
These brackets will maintain the required 1” 
clearance between the back of the unit and a 
combustible surface.   
 
 
Outdoor Installation 
 
Follow all local codes, or in the absence of 
local codes, follow the codes for Installation of 
Gas Burning Appliances; National Fuel Gas 
Code ANSI Z221.23 in USA or CAN/CGA 
B149.1 or .2 in Canada.  
For outdoor installation, purchase a TK-TV04 
and install on the top of the unit. 
Set the dipswitches for an outdoor installation 
(See pgs. 21-22). 
Locate the water heater in an open, unroofed 
area, and maintain the following minimum 
clearances from combustible and 
noncombustible materials. 
 
 
Outdoor Clearances 
Piping side 
6” 
Front (Maintenance 
space) 
24” 
Floor Non 
combustible 
base Min.  3” off the 
ground 
Back of heater 
1” 
Non piping side  
2” 
Top of heater  
36” 
 
If this unit is installed under an overhang, 
there must be a 36” clearance from the top of 
the unit to the overhang, and the surrounding 
area must be open in front and on the sides of 
the unit. 
 
WARNING: Do not have the flue terminal 
pointing toward any opening into a building. 
Do not locate your heater in a pit or any 
location where gas and water can accumulate.