WARNING: Do not install the heater where 
water, debris, or flammable vapors may get 
into the flue terminal. This may cause damage 
to the heater. 
 
 
WARNING: United States regulations forbid 
installing the unit within 4’ of any opening into 
any building.  Similar Canadian regulations 
forbid the unit from being installed within 10’ of 
any opening into any building.  
 
WARNING: Improper installation can cause 
nausea or asphyxiation from carbon monoxide 
and flue gases which could result in severe 
injury or death. 
For installation in altitudes above 4,500 feet, 
contact the manufacturer for instructions. 
 
Indoor Installation 
 
Follow all local codes, or in the absence of 
local codes, follow the codes for Installation of 
Gas Burning Appliances; National Fuel Gas 
Code ANSI Z221.23 in USA or CAN/CGA 
B149.1 or .2 in Canada. 
WARNING:  In an indoor installation, the T-K2 
must be connected to a Category III special 
gas vent in order to direct the dangerous 
exhaust byproducts to the outdoors. 
Connect the 4” Category III vent pipe to the 4” 
round collar on the top of the unit. 
WARNING: Do not install the unit directly on a 
combustible surface such as carpeting, wood 
floors, etc.  If it is necessary to install the unit 
standing on a surface, install a 3” 
noncombustible base between the unit and the 
surface. 
Combustible Air Supply 
The T-K2 must be installed in a location where 
the proper amount of combustible air will be 
available to it at all times.  If the unit is 
installed in a confined space, there must be 
permanent openings supplying air to the unit. 
If the openings will bring air directly from the 
outdoors, two openings are required, and they 
should be sized to give a minimum free area 
of one square inch for every 4000 BTUH of the 
maximum input rating of the unit.   
 
 
                                            Air Vents 
  T-K2 
 (47 
sq. 
in. 
 
 
 
              each) 
 
If the openings will bring air from another 
indoor area, they should be sized to give a 
minimum free area of one square inch for 
every 1000 BTUH of the maximum input rating 
of the unit.   
 
                  Air Vents 
                 (185 sq. in.            T-K2 
                     each) 
One of these openings should be within 12” of 
the ceiling, and the other should be within 12” 
of the floor.