SERVICE (CONT.)
AUXILLARY CONTROL BOARD (FMD DBC-3 only)
FIG. 6 AUXILIARY CONTROL BOARD
P4102.40
Location:
The auxiliary control board is located behind the lower 
front access cover, mounted on the rear side of the 
component bracket.
Hot Water Dispense
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  With a voltmeter, and using the component mount-
ing bracket as a reference (-), back probe check 
for voltage at pin 1 (red wire) of J1. Connect the 
dispenser to the power source. The indication must 
be approximately 37 volts dc.
3.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to step 5. If 
voltage is not present as described, refer to the wiring 
diagram and check the dispenser wiring harness.
4.  Back probe check the voltage across pins 2 (black 
wire) and 5 (white wire) of the six pin J2 connector 
on the wiring harness with a voltmeter. Connect the 
dispenser to the power source. The indication must 
be:
 
a) 120 volts ac for two wire 120 volt models
 
b) 120 volts ac for  three wire 120/208 or 120/240 
volt models 
 
c) 240 volts ac for two wire 240 volt models.
 
d) 230 volts ac for two wire 230 volt models.
5.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to step 6. If 
voltage is not present as described, refer to the wiring 
diagram and check the dispenser wiring harness.
6.  Check the voltage across the terminals of the hot 
water dispense solenoid with a voltmeter. Connect 
the dispenser to the power source. Press the hot 
water dispense switch. The indication must be: 
 
a) 120 volts ac for two wire 120 volt models
 
b) 120 volts ac for  three wire 120/208 or 120/240 
volt models
 
c) 240 volts ac for two wire 240 volt models.
 
d) 230 volts ac for two wire 230 volt models.
7.  Disconnect the dispenser from the power source.
If voltage is present as described the hot water dispense 
circuitry is operating properly. If voltage is not present 
as described, replace the auxiliary control board.
Ready Light Circuit
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  With a voltmeter, and using the component mount-
ing bracket as a reference (-), back probe check 
for voltage at pin 1 (red wire) of J1. Connect the 
dispenser to the power source. The indication must 
be approximately 37 volts dc.
3.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to step 4. If 
voltage is not present as described, refer to the wiring 
diagram and check the dispenser wiring harness.
42672 122209