SERVICE (cont.)
COMPRESSOR & COMPONENTS (CDS-3) (cont.)
Compressor  Thermal  Overload  Protector:  Refer  to 
FIG. 17
1.  Remove terminal cover retainer (7) and terminal 
cover (6).
2.  Remove the wire from thermal overload protector 
from the compressor wiring harness to the thermal 
overload protector.
3.  Remove overload protector retainer (5) and thermal 
overload protector (4) as an assembly
4.  Remove retainer (5) from overload protector (4) 
and discard overload protector.
5.  Install retainer (5) on new overload protector (2).
6.  Install retainer (5) and overload protector (4) on 
the compressor terminal bracket.
7.  Refer to Fig. 20 and reconnect the thermal overload 
protector wires.
8.  Reinstall  terminal  cover  (6)  and  cover  retainer 
(7).
FIG. 20 THERMAL OVERLOAD PROTECTOR 
TERMINALS
Compressor Start Relay
WARNING: The compressor start capacitor must be 
properly discharged before proceeding.
1.  Disconnect the wires from the compressor relay.
2.  Remove the #6-32 screw securing the relay to the 
rear of the component bracket.
3.  Remove and discard relay.
4.  Install  new  relay  on  the  rear  of  the  component 
bracket and secure with a #6-32 screw.
5.  Refer to Fig. 19 and reconnect the wires. 
FIG. 19 COMPRESSOR RELAY TERMINALS
5
6
4
1
2
T4 WHI from Compressor
and Main Harness
T4 BLK from Run Capacitor
T5 BLK from Compressor
Thermal Overload Protector
and Main Harness
T1 BLK from Start Capacitor
T2 BLK from Run Capacitor
T2 Red from Compressor
P1820
BLK to Compressor Relay T5
P1821
START
RUN
BLK to Compressor
Relay T1
BLK to Compressor
Relay T6
BLK
BLK to Compressor
Relay T2
P1817
FIG. 18 COMPRESSOR CAPACITOR TERMINALS
Compressor Start Capacitor: 
WARNING: The compressor start capacitor must be 
properly discharged before proceeding.
1.  Disconnect the two leads on the compressor start 
capacitor. 
2.  Loosen the capacitor retaining strap and remove 
the capacitor.
3.  Securely install new start capacitor under the retain-
ing strap.
4.  Refer to Fig. 18 and reconnect the wires to the start 
capacitor.
Compressor Run Capacitor: 
WARNING:  The  compressor  run  capacitor  must  be 
properly discharged before proceeding.
1.  Disconnect the three leads from the compressor 
run capacitor.
2.  Loosen the capacitor retaining strap and remove 
the capacitor.
4.  Securely install new run capacitor under the retain-
ing strap.
5.  Refer  to  Fig.  18  and  reconnect  the  wires  to  the 
relay.
27646  122200