Bunn Beverage Dispenser CDS-3 Manual De Usuario

Descargar
Página de 60
8
ICE CONTROLS
Controls the consistency of the ice in the hoppers 
when  the  DAY/NIGHT  switch  is  in  the  left  “DAY” 
position and the ICE/OFF/NO-ICE switch is in the left 
“ICE” position.
Turn this control clockwise to produce a 
coarser ice or counterclockwise to produce 
a finer ice. (The dispenser is set to deliver 
satisfactory ice at a 1:00 setting.)
AUGER SWITCHES
 ”—” –
 This is the normal operating posi-
tion. Energizes the auger motor when in 
the right position. The dispenser will cool 
to the ice consistency or liquid temperature 
presets  only  with  the  switch  in  the  right 
position.
“o” – Removes power from the auger mo-
tor when in the left position.
POWER OFF/ON SWITCH
ON –
 This is the normal operating position. The dis-
penser is electrically energized when the switch is in 
the right “ON” position. NOTE – The compressor will 
start after a 3 minute 20 second delay on the CDS-2 
and a 6 minute 30 second delay on the CDS-3.
OFF – All electrical components of the dispenser are 
without power when the switch is in the left “OFF” 
position.
ICE/OFF/NO-ICE SWITCHES
ICE –
 This is the normal operating position. Freezes 
and  maintains  the  ice  in  the  selected  hopper  to  the 
consistency set with the ICE control(s) when in the left 
“ICE” position.
OFF – Provides no cooling to the selected hop-
per when in the center “OFF” position.
NO-ICE – Maintains cooling yet allows any ice 
in the selected hopper to naturally thaw when 
in the right “NO-ICE” position.
DAY/NIGHT SWITCH 
DAY – This is the normal operating position. 
The hoppers’ display lights will glow and the 
electronic controls will maintain ice when the 
switch is in the left “DAY” position, the indi-
vidual hoppers’ ICE/OFF/NO-ICE switches are 
in  the  left  “ICE”  position,  and  the  individual 
hoppers’ AUGER switches are in the right   “” 
position. 
NIGHT – Use this position at night. The hop-
pers’ display lights will be out yet  the  liquid 
will be kept cold in all hoppers when this switch is in the 
right “NIGHT” position and the AUGER switches are in 
the right “”position.
NOTE:  When Day/Night Timer is used, the Day/Night 
Switch in the control drawer must be kept in the “DAY” 
position.
POWER  INDICATOR    (Located  on  the  front  of  the 
drawer)
Glows to show that the POWER OFF/ON Switch is in the 
right “ON” position.
STATUS INDICATORS 
The electronic controls continuously diagnose the operational status of the dispenser and indicate as listed:
FLASHING 50% ON / 50% OFF – Glows while preparing for coolant to flow to the selected hopper. (Flashes for 
10-seconds, then glows steady for two minutes.)
STEADY GLOW – Glows for two minutes before coolant flows to the selected hopper, then continues to glow 
while coolant flows.
The electronics also sense and indicate error conditions in the dispenser as listed:
ONE FLASH EVERY FOUR SECONDS – Cooling is needed by the selected hopper, but the auger isn’t turning. Try 
placing the AUGER switch for the selected hopper in the right “” position.
OPERATING CONTROLS
 
(CDS-3 Controls Illustrated)
27646 022500