Bunn VLPF Manual De Propietario

Descargar
Página de 28
Page 14                                    
BREW TIMER (early models)
SERVICE (cont.)
Location:
 
The brew timer is located in the hood, to the right 
of the tank.
Test Procedure:
1.  Disconnect the brewer from the power source 
and separate the polarized, three-pin connectors 
between the timer and brewer wiring harness and 
rotate the brew timer dial fully counterclockwise.
2.  With a voltmeter, check the voltage across sockets 
2 & 3 (white and black wires) of the female con-
nector when the On/Left switch is in the upper 
position. Connect the brewer to the power source. 
The indication must be 120 volts ac.
3.   Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4.  If 
voltage is not present as described, refer to the  Wiring 
Diagram and check the brewing harness.
4.  With a voltmeter, check the voltage across sockets 
1 & 2 (blue and white wires) of the female con-
nector when the On/Left switch is in the upper 
position and the Start switch is pressed to the 
lower position and held. Connect the brewer to the 
power source. The indication must be 120 volts 
ac until the Start switch is released.
5.  Disconnect the brewer from the power source.
If voltage is present as described, reconnect the po-
larized, three-pin connectors, and proceed to #6.  If 
voltage is not present as described, refer to the Wiring 
Diagram and check the brewer wiring harness.
5
WHI to Relay Coil
BLK to Relay Coil
P1  BLU/BLK  to Start Switch
P2  WHI to Liquid Level 
     Board                       
P3  BLK to Relay
P1980.80
FIG. 3 BREW TIMER WIRING
OLD STYLE
6.  Disconnect the in-line connectors on the black 
and white wires from the timer to the wiring har-
ness.
7.  With a voltmeter, check the voltage across the 
black and white wires when the On/Left switch is in 
the upper position and the Start switch is pressed 
to the lower position and released. Connect the 
brewer to the power source. The indication must 
be 120 volts ac for approximately 20 seconds and 
then return to its previous indication.
8.   Disconnect the brewer from the power source.
If voltage is present as described, the brew timer is 
operating properly. Reset the timer dial as required, 
to obtain the desired brew volume. If voltage is not 
present as described, replace the brew timer.
Removal and Replacement:
1.  Separate all connectors between the brewer wiring 
harness and the timer.
2.  Remove the two #8-32 nuts holding the timer to 
the inside of the hood.
3.  Install the new timer circuit board as described 
in Late Model Timer section on the following 
pages.
4.  Refer to FIG. 5 when reconnecting the wires.
5.  Install the Timer Setting decal provided with the 
replacement timer kit, on the bottom of the top 
cover.
6.  Adjust the timer as required. Refer to Late Model 
Timer section on the following pages.
P1979.75
FIG. 2  BREW TIMER
10179 060100