TROUBLESHOOTING (cont.)
PROBLEM
Equipment will not operate
Brew cycle will not start
Automatic refill will not operate 
after drawing hot water.
PROBABLE CAUSE 
1. No power or incorrect voltage
1. No water
2. Water strainer/Flow Control
3. On/Left switch
4. Start switch
5. Brew timer
6. Relay
7. Solenoid valve
1. On/Left switch
REMEDY
(A) Plug in brewer.
(B) Check wall outlet for 120V ac
(C) Check circuit breaker/fuse.
Check plumbing and shut-off 
valves.
(A) Direction of flow arrow must 
be pointing towards brewer.
(B) Remove the strainer/Flow con-
trol  and check for obstructions. 
Clear or replace.
Refer to Service - On/Left switch 
for testing procedures. See page 
22.
Refer to Service - Start switch for 
testing procedures. See page 26.
Refer to Service - Brew timer for 
testing procedures. See page 16.
Refer to Service - Relay for testing 
procedures. See page 23.
Refer to Service - Solenoid valve 
for testing procedures. See page 
25.
(A) The On/Left switch must be 
in the upper position for the au-
tomatic refill to operate.
(B) Refer to Service - On/Left 
switch for testing procedures. See 
page 22.
10179 060100