NEW SPRAY FLOW
XX.X OZ/M
ENTER OZ  XX.X
(-)        DONE        (+)
CALIBRATE FLOW?
NO                     YES
SPRAYHEAD CAL?
NO                     YES
CONTAINER RDY?
QUIT                   YES
CALIBRATE SPRAY
PRESSBREWSTART
CALIBRATE SPRAY
60 SEC TO FINISH
COUNTS DOWN
TO ZERO
AFTER 1 MINUTE
BREW PRESSED
EXIT TO THE
NEXT FUNCTION
SCREEN
CALIBRATE FLOW
 
This function allows the operator to enter the actual 
flow rate of the sprayhead and the bypass by dispens-
ing both separately for one minute. The volumes are 
then entered in ounces per minute. (Oz/M)
Procedures to calibrate the sprayhead flow rate:
1.  Place a container, accurately graduated in ounces, 
and with a minimum capacity of 60 ounces, beneath 
the funnel on the brewer.
2.  Press and hold the ® pad until the display reads 
SET NEW RECIPES. Release the ® pad. Press and 
release the ® pad until the display reads CALIBRATE 
FLOW.
3.  Press and release YES to advance to the SPRAY-
HEAD CAL? function screen. (Pressing NO in the 
CALIBRATE FLOW screen will advance to the next 
function screen, BREW COUNTERS).
4.  Press and release the YES pad. The display should 
read CONTAINER READY? If the container is under 
the funnel, press YES. The display should read 
CALIBRATE SPRAY .. PRESS BREW TO START.
5.  Press and release the 
 pad. The display should 
read CALIBRATE SPRAY .. 60 SEC TO FINISH. The 
60 second timer on the display will count down to 
zero. When the counter reaches zero, the display 
will change to ENTER OZ.,  along with a number 
measured in ounces per minute.
6.  Measure the amount of water in the container and 
using the (-) or (+) pads, adjust the amount on 
the display to match the amount in the container. 
Then press DONE.
7.  The display should now read NEW SPRAY FLOW
along with the correct flow rate of the sprayhead 
in ounces per minute. After about 5 seconds, 
the display will return to the CALIBRATE FLOW 
screen.
8.  To exit the CALIBRATE FLOW program, press NO 
to advance to the next function screen, or press  
the 
 pad located on the front switch panel to 
exit the CALIBRATE FLOW function and return to 
the MAIN SCREEN.
P2307
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
34025  022509