Installation continued-
 
 
VENT-AIR INTAKE SYSTEM INSTALLATION 
 
      
WARNING 
The vent-air intake system must be properly installed.  Failure to 
properly install the vent-air intake system could result in property 
damage, personal injury or death. 
 
Do not install any damaged vent-air intake system components.  
Contact the manufacturer of the water heater for replacement parts.  
 
Tools Required For Vent-Air Intake Installation 
The following minimum tools are required to properly install the vent-
air intake system.  Note:  Wall construction will determine tool usage.
 
 
Tape Measure 
 
 
 
 
 
Drill 
3/16 inch Diameter Drill Bit(s) 
1/8 inch Diameter Drill Bit(s) 
Masonry Drill Bit(s) 
(For Poured Concrete, Concrete Block and Brick Wall 
Construction)
  
Reciprocating Saw
 w/appropriate Blade(s) (Dependent on Wall 
Construction) 
Chisel 
 (For Poured Concrete, Concrete Block and Brick Wall Construction) 
Hammer (For Poured Concrete, Concrete Block and Brick Wall  
Construction)
 
1/4 & 5/16 inch Nut Drivers  (Preferred) or Slotted Head Screwdriver 
Phillips Head Screwdriver 
IMPORTANT 
When the following instructions specify, to seal a vent-air intake joint, 
use only Loctite Ultra Blue 587 RTV Silicone sealant.  A tube of Loctite 
Ultra Blue 587 RTV Silicone sealant is supplied with every direct vent 
water heater and each optional vent-air intake kit.  Make sure that all 
joints are completely sealed. 
 
When drilling pilot holes for the #8 sheet metal screws through the 
five (5) inch (12.7 cm)
 diameter components, be careful not to drill into 
the inner three (3) inch (7.6 cm)
 diameter components.
 