Installation (Vent-Air Intake System Installation) continued-
 
 
1.  Measure the vertical height “Y” required in your installation.  (See Figure 
6).  Reference the appropriate Table A to determine number of vent-air 
intake kits required in your installation. 
 
2.  Measure the horizontal length “X” required in your installation (See Figure 
6).  Reference Table A to determine number of vent-air intake kits required 
in your installation. 
 
3.   Cut a 5-1/2 inch (14 cm) diameter minimum clearance hole in the wall at 
the point where the vent-air intake tubes will pass through the outside wall 
and connect with the direct vent-air intake terminal   
 
(See Figure 6). 
 
4.  From outside the building, position the outer wall mount plate and direct 
vent-air intake terminal over the center of the opening.  Mark the mounting 
screw hole locations.  With a 3/16 inch diameter drill bit (not supplied), drill 
holes for the wall anchors (supplied).  Install the wall anchors but DO NOT 
affix the outer wall mount plate and direct vent-air intake terminal to the 
wall at this time (See Figure 7).  Note:  Certain construction of walls may 
require the use of a different type of wall anchoring means than supplied.  
DO NOT modify the direct vent-air intake terminal or outer wall mount 
plate. 
 