TROUBLESHOOTING (cont.)
PROBLEM
Dripping from sprayhead
Water flows into tank continu-
ously (ON/OFF Switch "ON")
Water flows into tank continu-
ously (ON/OFF Switch "OFF")
Beverage overflows dispenser
Weak beverage
PROBABLE CAUSE
1. Syphon System
2. Lime Build-up
CAUTION - Tank and tank compo-
nents should be delimed regularly 
depending on local water condi-
tions. Excessive mineral build-up 
on stainless steel surfaces can 
initiate corrosive reactions resulting 
in serious leaks.
3. Brew Solenoid Valve
1. Brew Timer 
1. Brew Solenoid Valve 
1. Dispenser
2. Brew Timer 
3. Brew Solenoid Valve
1. Filter Type
2. Tea
3. Sprayhead
REMEDY
The brewer must be level or slightly 
lower in front to syphon properly.
Inspect the tank assembly for ex-
cessive lime deposits. Delime as 
required.
Refer to Service  - Brew Solenoid 
Valve for testing procedures. See 
page 14
Refer to Service - Brew Timer for 
testing procedures. See page 15
Refer to Service - Brew Solenoid 
Valve for testing procedures. See 
page 14
The dispenser must be completely 
empty before starting a brew cycle.
Refer to Service - Brew Timer for 
testing procedures. See page 15
Remove the Brew Solenoid Valve 
and clean any obstruction. Rebuild 
or replace the valve if necessary. 
See page 14
BUNN
®
  paper filters must be used 
for proper extraction.
A sufficient quantity of fresh, loose 
tea leaves should be used for 
proper extraction.
A six-hole stainless steel spray-
head must be used for proper  
extraction.