TROUBLESHOOTING (cont.)
PROBLEM
Weak beverage (cont.)
Dry tea leaves remain in the fun-
nel
Brewer is making unusal noises
PROBABLE CAUSE
4. Funnel Loading
5. Water Temperature
6. Low Brew Water Volume
1. Funnel Loading
1. Solenoid(s)
2. Plumbing Lines
3. Water Supply
4. Tank Heater
REMEDY
The BUNN
®
 paper filter must be 
centered in the funnel and the bed 
of tea leaves  leveled by gentle 
shaking.
Place an empty funnel on an empty 
dispenser beneath the sprayhead. 
Initiate a brew cycle and check the 
water temperature immediately be-
low the sprayhead with a thermom-
eter. The reading should not be 
less than 200°F. Adjust the control 
thermostat to increase the water 
temperature. Replace if necessary.
Adjust needle valve to achieve 76 
oz. water from the sprayhead when 
the batch size setting is at three 
gallons.  To increase volume, turn 
counter-clockwise.  To decrease 
volume, turn clockwise.
The BUNN
®
 paper filter must be 
centered in the funnel and the 
bed of tea leaves leveled by gently 
shaking.
The nut on the solenoid(s) must 
be tight or it will vibrate during 
operation.
Plumbing lines should not be rest-
ing on the counter top.
(A) The brewer must be connected 
to a cold water line.
(B) Water pressure to the brewer 
must not exceed 90 psi(621 kPa). 
Install a regulator if necessary to 
lower the working pressure to ap-
proximately 50 psi(345 kPa).
Remove and clean lime off the tank 
heater. See page 22