PROGRAMMING THE DISPENSER
Press the Right Hidden Switch for 5 sec. to enter the programming menu. Use the Left and Right hidden 
switches to scroll through the menu screens. Select Exit to leave the programming function and return to normal 
operations.
NOTE 1: Flashing menu items indicate which selection is active.
NOTE 2: Values shown below are the factory default values for English units.
NOTE 3: Values in [X - X] are the Min. and Max. for that function.
READY
SELECT FLAVOR
 
LEFT DISP RATIO
(-)  30:1  (+)
 
MID DISP RATIO
(-)  30:1  (+)
RIGHT DISP RATIO
(-)  30:1  (+)
LF DISP VOLUME 1
(-)  36.0oz  (+)
LF DISP VOLUME 2
(-)  192.0oz  (+)
LF DISP VOLUME 3
(-)  384.0oz  (+)
MID DISP VOLUME 1
(-)  36.0oz  (+)
MID DISP VOLUME 2
(-)  192.0oz  (+)
MID DISP VOLUME 3
(-)  384.0oz  (+)
RT DISP VOLUME 1
(-)  36.0oz  (+)
RT DISP VOLUME 2
(-)  192.0oz  (+)
RT DISP VOLUME 3
(-)  384.0oz  (+)
 
LCD DISPLAY 
ACTION 
DESCRIPTION
Hold the RT Hidden Switch 
for 5 seconds to enter 
Programming Functions
Use the (+) or (-) buttons to 
adjust the Mix Ratio
Use the (+) or (-) buttons to 
adjust the Mix Ratio
Use the (+) or (-) buttons to 
adjust the Mix Ratio
Use the (+) or (-) buttons to 
adjust the Volume
Use the (+) or (-) buttons to 
adjust the Volume
Use the (+) or (-) buttons to 
adjust the Volume
Use the (+) or (-) buttons to 
adjust the Volume
Use the (+) or (-) buttons to 
adjust the Volume
Use the (+) or (-) buttons to 
adjust the Volume
Use the (+) or (-) buttons to 
adjust the Volume
Use the (+) or (-) buttons to 
adjust the Volume
Use the (+) or (-) buttons to 
adjust the Volume
Normal Display for LCR models.
 
Enter the desired Mix Ratio for the concentrate 
used in the Left dispenser. [25:1 - 100:1]
Enter the desired Mix Ratio for the concentrate 
used in the Middle dispenser. [25:1 - 100:1]
Enter the desired Mix Ratio for the concentrate 
used in the Right dispenser. [25:1 - 100:1]
Set the desired SMALL portion control volume:
(0 - 640 oz) or (0 - 18.93L)
Set the desired MEDIUM portion control volume:
(0 - 640 oz) or (0 - 18.93L)
Set the desired LARGE portion control volume:
(0 - 640 oz) or (0 - 18.93L)
Set the desired SMALL portion control volume:
(0 - 640 oz) or (0 - 18.93L)
Set the desired MEDIUM portion control volume:
(0 - 640 oz) or (0 - 18.93L)
Set the desired LARGE portion control volume:
(0 - 640 oz) or (0 - 18.93L)
Set the desired SMALL portion control volume:
(0 - 640 oz) or (0 - 18.93L)
Set the desired MEDIUM portion control volume:
(0 - 640 oz) or (0 - 18.93L)
Set the desired LARGE portion control volume:
(0 - 640 oz) or (0 - 18.93L)
41129.1 080112