Chaparral FS2620R Manual De Usuario

Descargar
Página de 100
FS2620R Rack Model User’s Guide
 
3-22
Table 3-4 shows the temperature and voltage thresholds for each alarm and what to do to 
resolve the problem. 
To enable or disable the alarm:
1
From the System Menu, select Configuration Menu and press Enter.
The Configuration Menu screen displays. 
2
Select Alarm and press Enter.
The Alarm screen displays. The current setting is marked with an * next to it.
3
Select the option you want and press Enter.
The system confirms that the changes are made. 
4
Press Enter to return to the Configuration Menu.
Table 3-4. Alarm thresholds
Alarm threshold
What to do when the alarm sounds
CPU temperature
Warning—0°C to 4°C and 
91°C to 100°C
Shutdown—<0°C and >100°C
!
Check the Router Administrator software to confirm 
what the alarm means. See 
!
Check that the CPU fan is running and is not 
obstructed. 
On-board temperature
Warning—0°C to 4°C and 
57°C to 61°C
Shutdown—<0°C and >61°C
!
You can feel if the fan is running by placing your hand 
on the rear panel of the router near the power switch.
!
Check the ambient temperature and lower it, if needed. 
Ambient temperature should be less than 45°C.
VCC voltage
Warning—5V -5.0% and +6.5%
Shutdown—5V -6.5% and +10%
!
Check the Router Administrator software to confirm 
what the alarm means. See 
!
If it is a warning alarm, let the router continue to 
operate.
!
If it is a shutdown alarm, turn off the power to the 
router and send it for service.
12V voltage
Warning—12V -10% and +10%
Shutdown—12V -20% and +20%
!
Same as above for the VCC voltage.